horizontal gas steam boiler for textile industry

Henan difference fast boiler horizontal steam boiler for textile industry steam boiler is a steam boiler with ordinary steam production machinery and equipment, generally used gas, or coal gas as a fuel, there are an electric steam boiler. Henan fast boiler for the inspection of the steam boiler is a steam boiler gas, fuel oil, gas, and it is common conventional steam boiler with the following differences: "steam boiler supervision norms" and the forthcoming introduction in June next year the new pot rules " boiler safety technology to monitor the specifications "are clearly defined steam boiler needs to be regulated by the state. In other words, users looking to buy a steam boiler plant boiler installation and can not be used directly. Before installation To pot seized by the approval and registration required for installation, and the need for inspection on a regular basis, usually one year during the annual inspection. But there are some of the steam boiler does not require registration and annual inspection, the old rules and the new pan pot regulations stipulate a water capacity less than 30L steam boiler is not within the scope of the surveillance. Because the water capacity of 30L water capacity than at home with a water heater are also small, so there is no risk of explosion, we do not need supervision. Henan water capacity fast boiler steam boiler 26L, belongs steam boiler does not require supervision. Steam boiler explosion hazards generated is amazing. In many steam boiler explosion in the boiler room were razed to the ground, the annual explosion of a steam boiler will be the first to cause casualties and significant economic losses. Henan fast boiler steam boiler is to achieve the ultimate, the boiler body through the scientific design, water capacity is very low, only 26L, itself, there is no risk of explosion on security. The thermal efficiency of conventional steam boiler is only 80%, while the party Henan boiler thermal efficiency of fast gas steam boiler can reach more than 93%. Henan plus energy-saving system fast boiler control systems, the actual energy savings up to 30%, running down a year could save hundreds of thousands of operating costs. The Henan fast boiler steam boiler without boiler room, an area itself is small, you can put in the basement or roof, it can also be placed directly next to the device requires the use of steam. Saving the cost of laying pipe network construction costs and the boiler room, a significant reduction in the use of the initial investment.

How much gas 6 tons per hour of horizontal steam boiler for textile industrys need? How much natural gas steam boiler needs an hour? 6 tons calorific gas steam boiler 360 million cards, the design pressure of 1.25MPa, the maximum steam temperature 194 degrees, consumption of natural gas per hour at full load boiler 420m3. The above data is only theoretical gas consumption, the actual gas consumption is influenced by many factors. 1, the thermal efficiency of the design; 2, insulation effect; 3, discharge times; 4, fireman professional level; gas and steam boilers are mainstream industrial production equipment. Especially since the implementation of the national coal gas policy, China has not yet biomass boilers and coal-fired boilers appear. Users select the gas-fired most important criteria are reasonably priced, low operating cost, easy to say and difficult choices. What price is only worth buying for key boiler, gas boiler selection is a measure of its quality, how to identify the quality of the boiler? 1, should be sufficient energy, emissions, low emissions; 2, low air consumption; 3, low operating costs; 4, stable; 5, long life; condensing gas boiler advanced design, for flue gas flow reasonable the design optimization. Sufficient heat transfer through the flue gas and smoke tubes economizer, heat the fuel sufficiently. Gas boiler for maximum energy efficiency.

Recently, Jinan City, Shandong Province People's Government issued and implemented the "2018 Beijing and Tianjin and the surrounding regions - 2019 autumn and winter tackling air pollution comprehensive management action plan" to inform the implementation of the program, requires the consolidation of ambient air quality improvement achievements, promote air quality continues to improve. On October 1, 2018 to March 31, March 2019, and all the city county fine particulate matter (of PM2.5) mean concentrations fell more than 2%, severe pollution and over several days up declining.

"Implementation plan" will be based on four construction industry, energy, transport and land use optimization adjustments to promote clean heating, public transferrin, enterprises mentioned standard upgrade, dust remediation, focusing on the consolidation of "scattered pollution" enterprise comprehensive rectification results, ruthless grasping diesel trucks, industrial furnaces and rectification of volatile organic compounds, heavy pollution to the implementation of the weather in autumn and winter peak load shifting production to strengthen joint prevention and control among regions, strengthen law enforcement supervision.

1, continued implementation of the total coal consumption control, strict implementation of national, provincial coal consumption reduction of about alternative work arrangements, and the development of alternatives seriously implement the Jinan City, the work reduction of coal consumption, coal consumption control tasks break down into individual counties, total coal consumption to achieve a steady decline. 2018, the city's total coal consumption control in less than 17.14 million tons.

2, effectively promote clean heating to the town (street) or the county as a unit as a whole. As of 2020, the city's pre-season heating living and improve the basic motivation for heating coal for alternative tasks, to develop a three-year implementation program to determine the annual task of governance. Taking into account the agricultural greenhouses, animal building bulk coal governance and to proceed with energy-saving buildings to improve energy efficiency. The county should proceed from reality, according to local conditions, reasonably determine the transformation of technical route, should the electric power, gas should the gas, the coal should be coal, should be hot is hot, and actively promote the use of solar thermal and centralized biomass utilization; adhere to highlight focus, give priority to urban life and motivation for heating gas demand, priority to promoting the urban bulk coal cleared. Gas will adhere to the reform, to change the electric set, on the basis of priority to the protection of residents in 2017 has started "coal to gas," "coal to electricity" project on gas electricity, gas and new year according to the actual supply and heating period the ability to reasonably determine the residents' coal to gas, "" coal to electricity "households; insist on legislation after the break, substitution of gas for coal to electricity instead of coal and other alternatives, in the implementation of air power is not the case, the original heating facilities will not be removed. In accordance with national, provincial requirements, to complete the clean winter heating construction tasks 33000.

3, complete replacement of the bulk coal areas to be designated as high-pollution fuel combustion zone ban in accordance with the provisions, shall not be burning coal for use again. Severely crack down on sales of low quality coal combustion, to ensure the quality of coal used in line with national and local coal quality standards.

Startup boiler steam temperature does not mention how high do? A: In the unit to start the process, often encounter steam pressure has reached the requirements, and the steam temperature was too much difference, especially in front of the turbine and the blast furnace or red switch occurs. Should take the following measures: appropriate to increase the amount of coal to improve the furnace heat load; adjust the secondary air ratio, increase the amount of lower secondary air; improve wind, air pressure, increased gas velocity; hydrophobic and full of air and exhaust mother pipe in front of the main steam isolation all hydrophobic.