2t oil gas fired steam boiler

To introduce 2t oil fired steam boiler pressure gauge and hydraulic press accumulator using steam boiler pressure gauge should pay attention to: 1, rated steam pressure is less than 2.45MPa steam boiler, the accuracy of pressure gauge must not be 2. 5; Rated steam pressure large or equal to 2.45MPa boiler, pressure must not be less than 1. 5 class. The diameter of the dial of the pressure gauge shall not be less than 100 mm to ensure that the operator can see clearly the surface pressure indicator value. 2. A red line should be drawn on the pressure dial of the steam boiler pressure gauge, indicating the maximum allowable working pressure. Steam boiler pressure gauges should be installed in a place that is easy to observe and wash. 4. Steam boiler pressure gauges should be checked at least once every six months, and should be sealed with lead after calibration. 5. Steam boiler pressure gauges should not have leakage of water and steam leakage in the connecting tubes of the pressure gauges of steam boilers. (4) the steam boiler pressure gauges should be checked at least once every six months and sealed with lead. 5. Otherwise, the pressure indicator value will be reduced. 6. The measurement range of the steam boiler pressure gauge should be adapted to the working pressure of the measured components, usually 1.5 times of the working pressure, preferably 2 times of the working pressure. Steam boiler does not have pressure gauge, the pressure gauge is damaged or the installation of pressure gauge does not meet the requirements, steam boiler pressure gauge should be stopped when one of the following conditions: 1, broken surface glass or dial calibration mold There is no clear paste; 2, no lead seal, lead seal damage or beyond the calibration period; 3, without pressure, the pressure gauge of the finite pin can not be restored to the limit pin, the infinite position of the gauge pointer deviated from zero data beyond the allowable pressure clothing; 4, gas leakage or pointer jump in the meter; 5, other defects that affect the accuracy of the gauge. Purpose of the accumulator: the accumulator is used in the hydraulic system of intermittent machinery, which stores the oil output of the hydraulic pump during intermittent or low-speed movement of the actuator, and when the rapid movement of the actuator requires a large flow rate, As an auxiliary energy source, together with the hydraulic pump, the oil pump is supplied to the system, thus the oil pump and the hydraulic pump are realized. The miniaturization of the whole hydraulic device absorbs the quick opening and closing of the impact hydraulic reversing valve and the sudden change of the load. The system will produce shock pressure, the darling will lead to vibration and noise, and even damage the machine. The accumulator can mitigate the impact pressure absorption pulsation of these fluids absorb and reduce the flow pulsation and pressure pulsation of various hydraulic pumps thus reducing the system noise and vibration. The damped accumulator acts as a gas spring and can be used to absorb the vibration between the fuselage and wheels of walking machinery such as vehicles. The balanced accumulator absorbs the gravitational potential energy of the vertical actuator (hydraulic cylinder) and its load as it falls. When the vertical actuator rises, the accumulator releases the original absorbed energy and supplies oil to the hydraulic cylinder together with the pump, thus realizing the balance and energy saving.

The use of central heating hot water boiler is the best choice for winter heating in northern China. Shanxi Province is located in Chang Darrow Heating Co., Ltd. mainly provides heating and post-service maintenance of heating equipment, heating clients involved in enterprises and institutions, office buildings, residential housing and a variety of commercial and other entertainment venues. With the wide blue sky covered Battle of the project, China's gradual increase in the proportion of heating for cleaning, heating, Ltd. Dalong Chang respond positively to the call of national policy, high pollution intensity wishing previously used, low thermal efficiency of coal-fired boiler to replace the traditional use hot water boiler clean fuel. After comparing many boiler manufacturers, choosing the optimal selection, determined and professional cooperation parties do fast boiler fuel boiler cleaning equipment. Providing a fast side 35 MW gas tube hot water boiler (SZS35-1.6-Y.Q) according to their actual needs.

When the pressure of the 2t oil fired steam boiler protection small small steam boiler pressure exceeds the rated boiler steam pressure protection, the need for chain protection: is shutdown, the system stops the combustion; fire mouth can also be varied, single-stage or two-stage combustion, You can adjust the amount of oil, so the buck, to ensure the safe operation of the boiler. Fuel (gas) pressure protection and steam boiler water, as the use of multiple protection: the pressure controller typically use two pressure controller, the pressure signal converted to an electrical signal, the electromechanical converter, the function of the high pressure, or low levels of signal The electrical switching loss, external circuits or automatic control chain protection. Common pressure controller and pressure gauge, vapor pressure overpressure alarm can cut off the burner limit is reached; pressure controller adjusts single fire or dual fire burning the actual operating pressure; for large burner, the pressure may be adjusted according to the size of the size of the amount of fuel, and always maintain a stable pressure relief valve operation is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design feature, the exhaust pressure relief, to ensure the normal operation of the boiler. Temperature protection temperature protection is an important procedure in the safe operation of the boiler, is particularly important for the regulation and protection of the boiler temperature steam; at the same time to regulate protective role in over-temperature hot water boilers. Conventional boiler temperature protection means is a bimetallic temperature controller.

Cause of abnormal gas 2t oil fired steam boiler stall phenomenon gas steam boiler and treatment of non-normal stalling reason, phenomena and treatment 2013-1-139: 17: 30 to cause a flameout: 1, or the operation of the auxiliary trip power outage. 2, boiler combustion instability. 3, the load is too low, so that the load sharply mill automatic ignition energy loss or failure of combustion. 4, mutant coal, volatile or low calorific value gas. 5, the automatic combustion flame detector failure or failure caused by tripping mill. 6, or blast furnace wall tubes serious improper boiler soot-blowing operation, a large amount of water vapor into the combustion chamber. 7, coal pulverizing system, fuel system failure, resulting in a significant amount of fuel reduction or interruption. Or with a large amount of water in the fuel oil gun blocked too many impurities, low pressure steam or atomized. Second, the phenomenon: 1, a significant increase in furnace pressure, furnace flame monitoring flameless CRT display. See the fire no fire hole, BTG warning window MFT warning lights. 2, the unit load decrease, the steam flow drops rapidly, each segment working medium temperature, the vapor pressure decreases, the value of oxygen surge. Third, the method of treatment: 1, if the MFT tripping protection, should an emergency shutdown processing, stop the supply of fuel. 2, identify the cause flameout, and try to eliminate, to conduct a comprehensive inspection of the boiler, after confirming the device properly, can restart.