Commercial 4t gas steam boiler Cheap Singapore

Comfortable life of people is inseparable from the northern winter heating boiler, normal, stable heat source is vital to people's lives. But the attendant is an increasingly serious environmental pollution problems, the implementation of coal to gas policy without delay, using the gas hot water boiler is the general trend. In order to achieve green heating, the National Tourism Administration Service Center decided to phase out the existing coal-fired boilers, the introduction of clean and environmentally friendly gas hot water boiler. Fast boiler with their own strong comprehensive strength and rich experience in the heating industry cooperation gained the trust of the National Tourism Administration Service Center, and ultimately provide a vacuum hot water boiler (T6-2800 2 sets of 2.8MW by fast Boiler ).

What is the working principle and composition of gas-fired commercial 4t steam boiler cheap singapore? Do you know any customer friends? The following is a technical explanation from the manufacturer of gas-fired steam boilers, which I hope will help you. A gas-fired steam boiler is a thermal energy conversion device that uses natural gas, liquefied gas, city gas and other gas fuels as fuel, burns the heat released from the furnace, heats the water in the pot, and vaporizes it into steam. The energy released from the combustion of a gas fuel in a boiler (pot) continuously heats up and the temperature rises to produce pressurized steam. The boiling point of water increases with the increase of pressure, and the seal of the boiler and the expansion of the water vapor are restricted to produce. Pressure is used to form thermal energy (the boiler's steam is strictly formed by constant pressure heating of water in the drum to re-vaporize saturated water) as an energy source. Gas-fired steam boiler is mainly composed of two main bodies, shell and furnace body, and an accessory, instrument auxiliary equipment, automatic control and protection system to ensure its safe and economical continuous operation. Gas-fired steam boiler is a boiler type boiler with water-cooled crucible. Gas-fired boiler has two return pyrotechnic tubes, arranged on the left and right sides, the front of the drum in front of the cigarette back. Between the roller and the lower box, there is a lower tube and a water-cooled manifold to form the frame of the combustion chamber. Roll There is a steam separator at the top of the tube to reduce moisture in the steam. The heating surface of the main body of the gas-fired steam boiler is the lower part of the drum, the water-cooled manifold and the pyrotechnic tube. It is very energy-efficient in gas-fired boilers. He has a high cost of fuel and liquefied gas and electric boilers. Gas-fired steam boiler is also a kind of protective boiler. When used, there will be dust and gas that damage our health. There will be no such problem with natural gas. The heat efficiency of gas steamer furnace is very high, can reach more than 90%! The point is that he has a long life. He uses very clean dyes, so he doesn't produce dust and smoke in the furnace when he burns. Grey, so his life is much longer than other boilers. In the development of boiler, he is developing towards the goal of environmental protection and energy saving.

The reason you need to know the boiler energy consumption (reheat steam temperature) reheat steam temperature problems 1. Circumstances reheat temperature rises 1.1 Move boiler furnace flame center, furnace outlet temperature increases (see main economic indicators No. 5 boiler exhaust gas temperature). 1.2 coal increased too fast. 1.3 Excess air amount is increased. 1.4 pulverizing system start-stop. 1.5 Automatic control of the reheater desuperheating water improper adjustment. 1.6 reheater sootblowing time poor choice. 1.7 feed water temperature is low. 1.8 the high pressure turbine exhaust temperature is high. Next to the 1.9 high leakage, high reheater inlet temperature. Hot and cold extraction section greater then 1.10. 1.11 boiler heating surface design is unreasonable, over-temperature reheater tube wall, forced cooling operation. 2. Reheat the following partial flame temperature is lowered center 2.1: burner tilt deviation, hem; burner is switched from the upper to the lower layer, the lower layer or to an excessive amount of the powder; volatile coal fraction is increased, the pulverized coal thinning, water reduction. 2.2 reheater heating surface fouling, slagging, fouling the interior. 2.3 Save reheat the heated drain valve. 2.4 automatic adjustment inappropriate, excessive reheater desuperheating water. 2.5 feedwater temperature. 2.6 economizer and water wall sootblowing time poor choice. 2.7 reduce the amount of coal too fast. 2.8 # 1, # 2 high pressure heater is disabled, increasing the reheated steam flow.

Electric boiler supplying domestic matters need to pay attention what? 1, electric boiler carefully check each system before opening oven parts electric boiler, focused on checking the three security controls pressure gauge, safety valve, gas pipe fittings, water level is normal, everything is correct, put on compliance clothing to continue to work. Electric commercial 4t steam boiler cheap singapore 2, please do one-handed operation when the water in the electric boiler, water regulatory action is single-handedly opened the door in one hand and a water injector steam valve, when the water column to a predetermined level, the first valving (valving time face not being on the water, to prevent splash injuries face) and then turn off the water gate, electric boilers provide domestic water to be alert order can not be reversed. When electric boiler work, surrounding someone must guard the moment the water level and pressure gauges, there can be no neglect of duty, to adjust work schedules when working at night, night shift work, be sure to have a good rest during the day, not at night when this work I would doze off, because if there is any carelessness, accidents will happen. Points to note what? 4, electric boilers night to the boiler daily sewage treatment, water table should clean up once every night. For motor and other mechanical equipment have always been its inspection, if any abnormal findings, the investigation must be immediate. Weekly safety valve should be checked whether it is safe.