system gas boilers

Steam Boiler Types in Sugar Mill

ZG Boiler is a prominent industrial steam boiler manufacturers, and it supplies coal fired steam boiler, biomass fired steam boiler, oil & gas fired steam boiler, waste heat steam boiler, CFB steam boiler to customers. When it comes to the term of steam boiler in sugar mill, it mainly uses bagasse as the fuel, therefore, biomass fired steam boiler is popular in sugar mill, and bagasse fired steam boiler for sale in ZG Boiler has the advantages of high efficiency, low combustion, energy saving, environment protection.

The calculated results indicate that the simulation values are consistent with the experimental values. Effect of system boilers load on the temperature of furnace, flue gas emission, inlet and outlet flue gas of economizer was discussed based on the model. Boiler load on the increase results in a increase in temperature of furnace, flue gas emission, inlet and outlet flue gas of economizer. The main performance parameters of 65t/h oil shale CFB boiler system were discussed and preliminarily predicted by the model.

Sales Director shared the 2017 summary of the work group marketing and marketing strategy in the 2018 General Assembly. 2018, the party will continue to move forward faster, increase marketing efforts, new product development efforts, service brand strength and marketing penetration efforts, multifaceted promotion, fully operational.

Gas-fired steam system boilers safety valve from installation to use, it must remain vigilant safety valve is one of the most important components of the gas steam boilers, boiler probability of the risk occurring due to various incidents can effectively suppressed. This article focuses on the safety valve from installation to use several important considerations, we do not ignore the use of gas when it steam boiler. A Notes 1 safety valve, the safety valve should be mounted vertically in a high position in the pot business, set box. 2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly. 4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm. 5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve. 6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. 7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve. 8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve. 9, separable economizer outlet, the steam superheater outlet valve must be installed.