heavy oil fired steam boiler hdpe bag

Henan gas treatment condensing boiler operation in the secondary combustion Accident Henan condensing gas boiler, deposited in the rear of the boiler flue gas condensing Henan combustibles (soot, carbon black) re-ignition combustion phenomenon called secondary combustion, also known as Henan condensing gas boiler flue tail and then burned. It will backpass severe, air preheater, induced draft fan and other equipment economizer even destroyed. 1. Henan condensing gas boiler secondary combustion phenomenon (1) a sharp rise in exhaust gas temperature, chimney to take smoke, fire or even smoke. (2) changes drastically furnace pressure, positive pressure occurs. (3) severe flue enclosure dark red. (4) when there is an air preheater, a sharp rise in the temperature of the hot air, pressure instability. (5) blast doors sometimes the tail action. Cause 2.Henan condensing gas boiler secondary combustion (1) poor atomization burner, oil, gas and incomplete combustion into the rear of the boiler. (2) combustion improperly adjusted, with insufficient wind or with the wind unreasonable. (3) Henan condensing gas boiler startup, shutdown during low furnace temperature, the unburned fuel in the furnace. (4) When shutdown or boiler fire, air gun valve is not closed. (5) the combustion chamber negative pressure is too large, too late to make the gas burn it into the rear of the boiler. (6) Long-term non-stop cleaning backpass furnace, accumulating a certain amount of soot or carbon black. (7) through the air preheater flue or leakage. 3. The gas processing condensed Henan secondary combustion boiler (1) should immediately stop the gas, stop the wind, shutdown. (2) closing the flue, and a baffle duct around the door opening, is prohibited to start sending, induced draft fan. (3) immediately extinguishing device into steam, carbon dioxide or other fire extinguishing means, (4) Strengthening Henan condensing gas boiler feed water and turn on the water, open the valve or economizer recirculation tube to protect the economizer is not burning. (5) When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C over 1h and stable openable inspection hole inspection, after checking element determines an ignition source, before the fan starts ventilation and cooling. (6) when the temperature drops below the flue 50 ℃, check before entering the flue tail heating surface, and should completely remove the flue soot. If not burning, can be re-started ignition; if burning, should be replaced, repaired burning member.

Boiler cleaning the necessity and significance of the boiler after a long run, the inevitable emergence of scale, corrosion problems, these problems are due to the generation of scale, so that the heat transfer deterioration, resulting in reduced efficacy boiler. It is difficult to achieve nominal evaporation; and since the heat transfer is deteriorated, such that the metal overheating, under pressure boiler, furnace tube bulge occurs even explode; poor thermal conductivity, so that the fuel consumption is increased, increased operating costs, boiler shortened life expectancy. Therefore, the boiler scale, should take the necessary cleaning methods. Of the boiler system operated at optimized state, it must be specialized chemicals treatment of boiler system water system: to remove scale, rust and anti-corrosion treatment: 1 chemical cleaning: adding a chemical cleaning agent to rust in the system , dirt, cleaning oil dispersion is discharged, reduced to clean metal surfaces; 2, routine maintenance: boiler scale inhibitor is added, to avoid rusting of metal, to prevent the crystalline precipitate calcium and magnesium ions. Boiler cleaning in two parts, part of convection boiler tubes, superheater tubes, air heaters, waterwall tubes scale, rust cleaning, i.e. water boiler water treatment, we used the final Li Jing Ling descaling operation, neutral cleaning technology cleaning operation, relatively low cost; cleaning of the part of the outer tube, i.e. the cleaning of the boiler furnace, we used high-pressure water jet cleaning technology, it is possible to achieve good results. 1, the cleaning operation may be neutral at neutral or weak alkalinity (pH 7-12) conditions, the water does not change the operation of the boiler a predetermined state index, do not stop cleaning, cleaning can reduce the loss caused by the stop, this is a the only signs of cleaning. 2, security theory and practice of running the boiler have proven non-erosive, washed acid-free cleaning under neutral conditions, the corrosion rate is less than the water washing of the corrosion rate of the metal, no corrosion damage to the metal. 3, non-toxic and pollution-free operation of the Spirit is a green cleaning products, boiler blowdown COD after its cleaning. BOD. The pH full compliance with national standards. 4, easy to use drugs added to the water supply can be, without a separate professionals, post operator can operate, it can be widely used. 5, a significant saving, the cleaning process in which water is the normal production water, unlike dispensing additional consumption pickling, passivation, and a large number of repeated washing of freshwater resources consumed. High pressure water jet cleaning technology uses water as the medium, so that the water system by special equipment to produce multi-beam, multi-angle, high-pressure water jets of different intensity. Internal cleaning object fouling, plugging, or be completely cut surface adhesion, crushed, pressed and washed in order to achieve complete cleaning. Whatever the fouling deposits, high pressure water jet cleaning device for cleaning, can be completely removed, which considerably metal color. It does not require chemicals, or corrosive flux, safety, and environmental protection. Boiler air preheater, waterwall, superheater, economizer heating surface and the like due to clogging of the exhaust gas temperature, boiler efficiency is lowered, increasing the wind electrical energy consumption; the fan will cause severe blockage afford pulling negative pressure oxygen furnace not enough, boiler forced outage. Using high pressure water jet technology, the cleaning effect is obvious. Equipment from high pressure water pump, water hoses, high pressure gun, special nozzle and other components. Cleaning process: water pressure via a high pressure pump to the 50 ~ 100Mpa, via line transferred to the system actuators work surface, forming a bundle of fine high-pressure water emitted from the nozzle with a high pressure water jet but powerful strike capability, which exit velocity up to 380m / s, the heating surface fouling rinse. The high pressure cleaning technology to clean, easy to adjust, cleaning equipment to be non-corrosive, non-polluting the environment, the effect is obvious characteristics, is an effective and a good way to save money and effort, especially suitable for solving air preheater clogging, severe coking furnace heating surface slagging problems. Generally reduce exhaust gas temperature of 4 to 12 degrees, the main improved reheat steam temperature of 0.5 to 5 degrees, to reduce electrical energy consumption for the wind, and early detection of creeping inflation, under scale corrosion risks, the unit safe and economic operation of very help.

Due to increase market demand for air conditioning, we increased the number of production lines, faced with the urgent need of a fired steam boiler hdpe bag problems. Emergence of fast boiler is time for us to solve this problem. From the start of contract manufacturing to transportation to our company for installation and operation, Fang fast only 35 days to solve our urgent needs. --customer feedback

10 tons of gas turbine fired steam boiler hdpe bag burner it currently requires 10 tons of steam gas boiler steam boiler there are two types WNS10-1.25-Q SZS10-1.25-Q, and two kinds, i.e., three horizontal wet return back structure and vertical type double drum "D" type arrangement quick water tube boiler. It consists of upper and lower drum, membrane wall, superheater, economizer and convection bank composition, the burner disposed on the front wall, the fuel combustion in the furnace, the flue gas through the first convection bank, superheater, a second convection economizer tubes and into the chimney. 10 tons of gas boiler burners have split and one-piece points, integrated burner fan I see are axial fans, centrifugal fans with split, 90% of the 10 tons of gas boiler burner all-in-one, as to form two burner what a good way, this has yet to be explored. SZS10-1.25-Q has the following features in gas boiler: The product has the following characteristics: ⑴ This double boiler drum "D" type arrangement, a compact, small footprint, good flame fullness. ⑵ boiler lower support mode can be free to expand upwards. ⑶ using membrane wall furnace wall structure which reduces maintenance work and use of refractory bricks. This boiler ⑷ fender an airtight closed welded structure, good sealing furnace wall; outer layer of pressed boards, appearance, beautiful. ⑸ this boiler furnace inspection hole is provided for the use, maintenance provides a great convenience. Roof has explosion-proof doors. This quick ⑹ boiler structure can effectively shorten the installation cycle. ⑺ high thermal resistance material as a heat insulating layer, good insulation properties. ⑻ economizer arranged tail, can effectively control the exhaust gas temperature, high thermal efficiency of the boiler. ⑼ whole boiler steel holder on a strong base, convenient installation and transportation. ⑽ boiler heating surface has a surplus, soft drinks and large enough space to ensure the stability of the boiler parameters. ⑾ using automatic burner, combustion efficiency and an ignition control program and overpressure, flame protection. ⑿ continuous electrically adjustable water supply, and having a low water level alarm, the protection function chain. ⒀ using spray desuperheater, sensitive temperature adjustment, temperature control large amplitude. Second, the structure Introduction boiler 1, the main evaporation rated specifications: D = 10t / h of superheated steam temperature: t = 300 ℃ superheated steam pressure: P = 1.25MPa water temperature: tgs = 20 ℃ (except normal saline) boiler efficiency: η = 92.6% exhaust temperature: tpy = 136.3 ℃ desuperheater tYPE: hydrostatic pressure test boiler desuperheater spray: 1.75 MPa number of valve: drum 2 PN2.5, DN80 full open spring valve overheating an outlet header PN2.5, DN50 full open spring valve design of the fuel: 0 light diesel oil (Qydw = 41870kJ / kg); consumption 749.9kg / h of natural gas (Qydw = 37060kJ / Nm3); 847.3 consumption Nm3 / h