8 ton Cheap boiler Energy Saving Laos

How steam 8 ton cheap boiler energy saving laos operation? Rules applicable to a range of operation of the steam boiler. 2.1 2 content steam boiler process equipment is high-pressure container, the operator must be well-known structures, explanation of the boiler performance and design, operation and obtain operating permits for technical examination in order to operate independently, it must be dressed labor duty products. 2.2 before ignition, each coping member ---- boiler display instrument, an electrical circuit, valves, cocks, pipes, water meter, pump, nozzles and various safety devices according to the procedure to check and confirm that no abnormal situation and leakage It may be started. Closing the hole in advance 2.3 Check the flue, the furnace and no foreign matter before proceeding. 2.4 start, programmed to check that the following do work: water meter; operation of water supply apparatus; low water cutoff operation; action pressure switch; pressure proportional control action; safety valve operation. 2.5 boiler blowdown should be run periodically (once per shift principle), blowdown, or prohibition hand hammer striking thereof with the drain valve opened, flushing water table once per shift. 2.6 boiler operation, the operator leaves his post allowed, when inspection tour should (in general a half-hour inspection, inspection records for one hour). 2.7 inspection tour should wear gloves, can not be touched with bare hands touch the heat conductive member, observe combustion furnace to wear protective glasses. 2.8 alarm has not met Ming, endless self-control or alarm malfunction, the scene was invalid or could not process should be shutdown immediately and report to the leadership process. 2.9 Where any of the following conditions should be treated immediately shutdown a) vapor pressure rises above the pole position, although the strengthening of water supply, steam safety valve has been ruled out, but the pressure continues to rise. b) serious water shortage c) the water level decreases rapidly (although the water supply, but still down) d) water gauge, pressure gauge, safety valves to malfunction. e) the furnace wall is damaged, a large number of smoke f) water supply equipment failure. g) the furnace leaking joints, deformation of the steel sheet, blister or crack is found. h) boiler full of water through drainage is still down. When the rear portion of i) the combustion flue found to have severe, or other polar operator safety risk. j) sudden onset of severe soda steam boiler or furnace Priming severe vibration. 2.10 into the furnace needs repair, you must shutdown before proceeding to cool to room temperature and adequate ventilation, cooling and insulation must take compulsory measures should only be approved by the leadership in case of emergency, and a person responsible for work safety monitoring . 2.11 chain boiler operation, its vapor pressure, air pressure, temperature must not exceed the specified pressure. 2.12 without permission not allowed to remove or destroy any safety valve, safety valve can not be automatically excluded from the operation of steam, shall report to the leadership of the exhaust valve with an artificial lift, and good maintenance. 2.13 When the general lack of water, they should be immediately "called water" tests, such as when the Department of severe water shortages, shutdown should be an immediate ceasefire to stop the water, such as the Department is not serious water shortages, slowly, a small amount of water, but must be strictly monitoring changes in a variety of instruments. 2.14 When shutdown when a cease-fire, before the air pressure drops to zero, the fireman can not leave their posts. 2.15 slag to be cleaned regularly, focused on targeted stacking. 2.16 boiler system must be checked to confirm a variety of instruments, alarms, safety devices intact, correct, sensitive before shift change. 3 Record 3.1 "fireman shift recording."

Which operating costs Food Factory Food Factory steam 8 ton cheap boiler energy saving laos steam boiler operating costs have what? Food factory, is the need to consider the cost of running the boiler, after all, spending in this area is great. Therefore, companies need to be accounted for costs in this regard. Because the boiler fuel costs can account for the total cost of running the boiler nearly 90%, other electricity boiler operation is put into the boiler (boiler and burner give (up) pump) lighting and electrical consumption, run-time power consumption), water consumption (water) boiler, labor costs (salaries), boiler maintenance costs. If food plants using natural gas-type gas boilers, steam boilers according to the required operating time per day every day the amount of steam and hot water boilers, above all converted to full-load operation time. Tonnage boiler unit with a gas (80 cubic meters per hour per ton of the boiler) and natural gas can be monovalent. 1 ton gas steam boiler, for example: (1) When the rated evaporation capacity of 1 ton / hour, fuel consumption is 70 cubic meters of natural gas, according to 3.5 yuan / cubic meter natural gas prices (around the price is not very different), natural gas cost of 70 to 3.5 million yuan to 245 yuan; (2) gas-fired boiler during normal use, power is 0.65 times, at full power, so the power capacity of the boiler (1.5kw + 2.2 kW 2 kW) * 0.65 = 3.7 kilowatt, if electricity is 1 yuan / kWh, the power boiler per hour 3.7kw * 1 = 3.7 yuan.

China Association of 8 ton cheap boiler energy saving laos and boiler water treatment boiler technology plays in the development of healthy and clean technology development and lead the industry in an important position, and boiler manufacturers are inseparable, in the future, the Group will soon square to maintain good communication with the Association to promote the technological innovation industry, enhance the technological level of the industry, promote the vigorous development of the boiler industry to contribute their efforts.

Electric 8 ton cheap boiler energy saving laos maintenance measures

In addition to the purchase of electric boilers need strict control of its quality and after-sales is good or bad, when in use should pay attention to some practices, so as to more effectively prevent harm to persons and property.