slaughtering and processing natural gas hot water atmospheric boiler supplier

What if there is wear and tear in the natural gas slaughtering and processing hot water atmospheric boiler supplier? Detailed inspection is the key, as is fuel management. According to the operation condition and time of natural gas boiler, we can plan reasonable wear inspection. When using fuel, we strictly control the granularity of coal and limestone. The size of bed material should be strictly controlled. Boiler waste should be disposed of. The waste residue of the boiler must be treated before it can be discharged. Natural gas boilers should be installed where heat is used, easy to install. The hot pipe should not be too long. It should have a good insulation. The pipe shall be tilted properly from the hot water outlet to the end. The water supply source shall be equipped with a control valve. To discharge exhaust gases, the chimney of the natural gas boiler should extend to the outside and the outlet should be 1.5 to 2M higher than that of the boiler. If we want to reduce the influence on the water wall tube, we can adjust the air pressure and air volume properly, and effectively reduce the wear of the water wall. Check time is usually standby or downtime. Items to be examined include wall wear, furnace sealing and smoke leakage. In case of wear and tear, repair and welding are required to ensure the normal operation of steam boiler. Generally speaking, before combustion of natural gas boilers, fossil fuels, fossil fuels and bed and circulating materials should be filled in the combustion chamber at wind speed and strength. And stiffness of the air convection under full integration. Furnace bottom air device, inner core area upward. The movement in the outer ring region flows downwards along the water wall of the furnace, thus prolonging the residence time of the coal particles in the furnace. Mineral particles, a large number of ash powder and smoke contain a large number of fly ash particles, these continue to lead to rapid wear of water-cooled wall tube, make wall thickness wear thin, resulting in wear.

Oil-fired slaughtering and processing hot water atmospheric boiler supplier technical analysis when equal sulfur content greater body oil and coal, low-temperature corrosion of boiler fuel in general is much more serious than a coal-fired boiler, for two main reasons: 1 coal-fired boilers, especially pulverized coal, coal 90% of the ash content of the flue gas is taken away, fumes generated in the sulfuric acid vapor is adsorbed fly ash in the flue gas, sulfuric acid vapor in the flue gas is reduced; coal combustion, about half of the sulfur remaining in the ash . While combustion of oil, the sulfur content of the fuel is almost complete conversion of SO2, the fuel ash few, little fly ash in the flue gas, the flue gas adsorption capacity of the sulfuric acid vapor is weak. 2. higher hydrogen content in the fuel, about 11% to 12%, per ton of fuel combustion can produce about one ton of water vapor, when the fuel in the flue gas water vapor partial pressure higher than when coal, lignite but because with water and more exceptions detailed in Table 1 below. When these two reasons that the fuel, the concentration of sulfuric acid vapor in the flue gas is large, when the sulfuric acid vapor in the flue gas is not only a so-called thermodynamic point of water vapor partial pressure is low is formed, as shown in Table 1. When the flue gas in a small amount of sulfuric acid vapor, the flue gas dew point of significantly increased. Effect of sulfuric acid concentration on the corrosion rate is large, typically at a sulfuric acid concentration of 40% to 50%, the fastest etching. Due to use of fuel oil-fired boiler, the flue gas dew point is not only high, but the sulfuric acid concentration in the air preheater heating surface is also formed large, low-temperature corrosion is worse than boiler fuel fired boilers.

Around the city to promote the coal to gas project, the major institutions of the heating system put forward higher requirements. Central Conservatory of Music is available to students and teachers clean, safe, comfortable, energy-efficient heating environment, protect the health of teachers and students, to transform the traditional slaughtering and processing hot water atmospheric boiler supplier treatment. Praise fast boiler Willie sharp series obtained in the transformation of low nitrogen boiler major institutions in Beijing, the Central Conservatory of Music in late 2017 with the signing of fast boiler boiler purchase contract, ordered six Willy sharp series V6-99, to for the entire school's heating facilities.

After the gas-steam circulation pump approach failed for some time to use gas steam oven, it will produce a precipitate. At this point, we need to clean heat transfer oil furnace, but before cleaning, we need to know what kind of sediment, and then cleaned the right way, if the heat transfer oil, grease appears very easy to make the wall thermal resistance increases, will increase the production of energy, gas steam liquidity will deteriorate, production will be reduced, the operating cycle will shorten the life of the device will be. Shorten, which in turn affect production. Some of the more common gas steam slaughtering and processing hot water atmospheric boiler supplier deposits are: sulfate, carbonate, silicon and iron. Acid sulfate does not bubbling, since relatively hard sulfates, carbonates decompose at high temperatures, the bicarbonate will dissolve, but the release of carbon dioxide will form an insoluble carbonate salt. When the temperature reaches 300 ~ 400 ℃, hot oil furnace thermally cracking occurs. It will produce carbon deposits on the inner wall and an inner wall, it affects the heat transfer efficiency. Easy to produce oil furnace heat transfer in high temperature environments. Thermal cracking, thermal polycondensation, and its kinematic viscosity increases, the fluidity deteriorates internal oxidation of the oil pipeline, oil conductive accelerated failure, the machine will be damaged, endanger human will be high. Steam oven gas processing cycle pump failure: (1) When the current is below the normal circulating pump, the circulating pump efficiency is lowered, the flow rate is reduced, the fouling of the heating pipe may be blocked, it should be cleaned. (2) circulating pump pressure constant, the current increases, flow decreases. Bad heat transfer fluid, the viscosity increased, should be replaced or regenerated. If the system does not remove water or aqueous decomposition newly heated conductive liquid should be immediately opened exhaust valve to the exhaust gas. (3) circulating pump current is reduced, the pump outlet pressure back to zero, indicating that the pump is not idle. It may be vaporized oil, gas and steam oven measures to find the cause vaporization; if the filter is clogged, the circulation pump should be evacuated and cleaned immediately opens the bypass filter; if the heating fluid contained in the new water or heated water, the system does not exclude the decomposition gas, the exhaust valves should be opened immediately exhausted.