Manufacturers Commercial 1t oil hot water boiler Nepal

Check gas boiler before the preparation of cease-fire and that the flue slow cooling drum; open all manholes and hand holes in the header of the boiler body; let go of the gas within the boiler drum and water; the boiler combustion chamber, drum , flue ducts thorough cleaning; steam pipeline cleaning and removing rust and scale water; repair or replace a manhole cover; ready safelight, flashlights, test rods, tools and the like. Burner gas is an important part of the boiler, the main control system and combustion system components, the problem lies in easy control cabinet, 1. However, the normal ignition off this failure phenomenon typical cause of several tens of seconds after the self-ignition of the burner flame sensor dirty parts. The flame sensor is a photoresistor when irradiated with light of its own resistance decreases resistance value increases as a state of high impedance low impedance state when the light irradiation. Burner flame sensor controller in accordance with a resistance value to determine whether the process is continued if the combustion stop combustion flame sensor high impedance supply is immediately stopped to prevent the unburned diesel fuel reservoir. Flame sensor probe positioned within the burner duct, since the black smoke, tempering, blowing dust and other reasons that the surface thus losing readily soiling the photosensitive functionality. Check sensor probe, its surface is cleaned with a detergent or alcohol, if necessary. 2. Ignition normal exhaust smoke color but not normal diesel fuel injected into the burner is burning the mixture under stirring, when the appropriate amount of blowing water vapor and CO2 exhaust gas atomization are colorless. When there is insufficient air supply can cause incomplete combustion of diesel soot to form CO and thus give rise to the phenomenon of black smoke exhaust. However, if a strong wind inlet excessive combustion of oil mist may be blown off too late will form white smoke is discharged. Common causes of black smoke exhaust of combustion into the throttle opening is too small, white smoke into the throttle opening is reason to see through the large, two cases should be re-adjusted into the throttle. Exhaust smoke color can be observed while the side damper opening degree until near colorless in exhaust smoke color adjustment. Another reason is that black smoke exhaust poor atomization of diesel, oil mist contained in the larger droplets, can not be sufficiently mixed with the air due to a local incomplete combustion produce soot.

Recently, Yuhang District, Hangzhou, Zhejiang Province, a printing company 20 steam tons / hour of coal-fired boilers have been stalled, this is the last Yuhang district an industrial coal-fired boilers, which marks the shutting down of Yuhang District of industrial enterprises to bid farewell to coal energy structure of coal turned to natural gas and other clean energy, Yuhang District from entering the industrial coal-free era.

Yuhang District "coal-free zone" construction of road resistance and long. As a major industrial zone, a long time, Yuhang District to focus on coal-fired thermal power plants, coal-fired boilers and other industrial enterprises formed a coal-dominated energy consumption structure. In 2014, the maximum amount of coal Yuhang District reached 783,600 tons. Large coal consumption that emissions of sulfur dioxide, dust and the like remain high for many years.

In order to further deepen the air pollution control, to win the Battle of the blue sky, Yuhang District, from 2017, will gradually tangqi thermoelectric, thermoelectric and sea Chongxian three coal-fired thermoelectric power plant with all closed down, the sea of ​​clean natural gas for thermoelectric realized heat. 3 thermal power plant shut down so that the region's coal consumption, pollutant emissions and other indicators to achieve substantial reductions in road construction of "coal-free zone" has taken a crucial step.

Yuhang bid farewell to coal road this did not stop. While coal-fired thermoelectric accounted for the bulk of coal consumption and pollution emissions, but only out of coal-fired power plant is not enough. 2018, the government decided to promote taking advantage of Yuhang District, the region within the remaining four coal-fired industrial enterprises (Coal Products) pot (kiln) furnace closed down or eliminated or modified.

Yuhang District to increase the proportion of electricity consumption, and actively guide the region's energy unit of coal to electricity, oil to electricity, gas bottle to electricity, the construction of an orderly distribution grid, promoting smart grid construction; continue to improve the level of utilization of natural gas, and urban area in addition to all the town cormorant birds, Baizhang full realization of natural gas supply, a total of 850 kilometers of natural gas pipeline construction and municipal gas transformation 45000; to promote the application of photovoltaic power generation, the region's industrial and commercial enterprises amounted to 173 megawatts of photovoltaic capacity building distributed, clean energy applications has taken shape in Yuhang District.

According to statistics, "Thirteen Five Year Plan" (2016-2020) since the implementation of environmental statistics included in Yuhang district industrial enterprises coal consumption from 588,900 tons in 2016 down to 38,900 tons in 2018, to drop in early 2019 0.

A substantial decline in coal consumption is brought to slash emissions of pollutants and air quality improved significantly. 2018, the main pollutant urban air Linping PM2.5 average concentration of 38 micrograms / cubic meter, decreased 40% in 2015. Region sulfur dioxide emissions of 7,833 tons in 2014 to 2018 had dropped more than 90%; NOx emissions to 8490 tons in 2014 to 2018 had dropped more than 60%.

In order to ensure boiler safety, to run smoothly, you must ensure that the use of high-quality natural gas. 1, equipped with one gas separator to increase the capacity, it can effectively store oil and water. Secondly, a level gauge designed to directly observe whether there is liquid in the separator. While the design of the automatic drain pressure relief device is installed. A single control pressure of the air is improved dual control, i.e. the pressure regulating valve is mounted on the main line to control the water separator, the pressure to stabilize, improve security purposes. 2, safety monitoring natural gas as a boiler room burning materials, natural gas leak monitoring must be done. The portable display technology poor performance, poor sensitivity. Host combustible gas alarm system with digital control scaling circuit having an alarm function and a secondary alarm, ensure the safe operation of the boiler. 3, check before firing the safe operation of: (1) whether the boiler inspection gates normally open or closed, check the gas pressure is normal, not too high or too low, open the supply valve leading to the boiler. (2) in the flue baffle must be fully open, otherwise it will affect the purge, causing accidents. Each knob and keep control cabinet to check the normal position. If the stove has a residue should be cleaned. (5) Check the boiler ignition and fire protection program control means should be flexible and reliable. Blast doors should be flexible and rigorous on the boiler. Before the completion of ignition, the ignition is not possible to start the ignition operation: After successful ignition, the load can be adjusted in the normal operation of the boiler when the combustion gas boiler adjusted. We should always observe the combustion furnace, and adjust the amount of steam, wind and steam pressure to ensure the safe operation of the boiler. Note: Program: first five minutes were furnace cleaning, automatic ignition after 5 minutes, observe the ignition is successful, the success of one minute after a small fire can be operated automatically converted to fire properly. For the boiler load and the air pressure adjusted by adjusting the pressure regulator to achieve. When adjusting the load, adjust the air pressure at the same time, it must be synchronized to adjust the air flow to ensure a reasonable match air volume and air volume, in order to achieve economic operation of the boiler. In normal operation, the amount of gas should not be adjusted or reduced drastically in order to avoid dramatic changes in combustion, the pressure receiving member sudden expansion, shrinkage and damage. When the boiler is running, the pressure gauge must be monitored regularly in order to maintain stable water pressure. BCP pressure changes observed, reflecting the relationship between water temperature and steam consumption. In the boiler operation, when the steam pressure is automatically adjusted, the main purpose of the staff is to monitor automatically adjusts the boiler system is sensitive and timely solutions to problems and ensure the sensitivity and reliability of the automatic control system. 4, first close the main valve shutdown operation, the air supply is stopped, the circulating pump and the water pump is still running, when the boiler water temperature falls below 70, and supplies or stops the circulation pump in operation of the pump after about 4 hours. Note: In addition to the accident and emergency parking stop, parking general approach should not cut off the power. After the shutdown, it is timely for the boiler and ancillary equipment to conduct a comprehensive inspection. If you find a defect in the device, and repair should be recorded at the time of shutdown. Safety Precautions 1. burner startup, if the burner is repeatedly locking and alarm, you should find out the cause of the malfunction, press the reset button after troubleshooting, press the reset button and then continue to boot. Note: Press the Reset button for less than 10 seconds. A lower burner inlet must be clean and clean, and does not allow offal. 2. burner once the ignition is unsuccessful, Boiler Fan should be restarted. Ventilation After 5 minutes, start the second startup burner igniter. three. During normal operation, the thermal device near the burner portion (e.g. flange connections) will be very hot, in order to avoid burns. Do not put flammable materials in the vicinity so as not to cause a fire. 4. The operation of the boiler circulating pump must be closely monitored and the manufacturers commercial 1t hot water boiler nepal pressure, gas distributor, pipeline valves, pressure gauges, flow meters, water level gauge and the like. 5. When the firefighters open the door or fire door observation, you should wear gloves and a side view. 6. A burner working environment should be kept clean and dry, in particular, a flame detector (i.e. electric eye) should be kept clean, part of the control circuit should humidity and temperature; class should cleaning and maintenance of a combustor. 7. During use, the filter should be cleaned regularly check or replace the filter cartridge in accordance with impurities of the fuel. 8. Check the electrical installations include: wire is damaged, the sheath is damaged, the screw is loose, the contact is good, whether the motor is running abnormal noise. Describes the advantages and disadvantages of natural gas boiler, editor of Sin sets introduced, the use of technology and safety precautions. Industrial boilers to energy efficient, environmentally friendly development direction. Natural gas boiler to meet the needs of these three points. They are the future of the boiler market trend, more and more restricted energy policy, energy saving and environmental protection requirements.

Low nitrogen vapor condensed steam boiler to heat water into steam in the boiler drum is widely used in hospitals, boiler water in the steam drum is heated to become the school, textile mills, garment factories, boilers clothing stores, garment factories, dry cleaners, restaurants, hotels, , bread shops, hotels, canteens, restaurants, food plants, beverage plants, soybean plants, meat plants, slaughterhouses, canneries, wineries, pharmaceutical, packaging factory, building materials factory, paint factory, beauty salon, sauna, steam room, baby swimming pool and other enterprises place. The fuel steam boiler may be classified into electrical steam boiler, steam boiler fuel, gas and steam boiler; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler compact than a single, double return vertical structure, the large steam boilers and more horizontal structure of three return. The fuel steam boiler (electricity, oil, gas) can be divided into an electrical steam boiler, gas manufacturers commercial 1t hot water boiler nepal CLSS vertical! Steam boiler fuel, gas steam boiler three kinds; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler mostly small and medium sized single, double backhaul vertical structure, more than three large steam boiler return horizontal structure. Refers to a steam boiler water heated to a certain temperature parameters, and the production of industrial steam boiler, water is heated into steam in the steam drum, the fire in the furnace emits heat, it is the principle of the steam boiler. Steam boiler belongs to special equipment, low nitrogen vapor condensing boiler of the steam boiler design, processing, manufacturing, installation and use must be supervised by technical supervision departments, users only get to use the boiler permits to use steam boilers.