Energy Saving Factory Price steam boiler 20t Singapore

Boiler plant equipment as three major important energy conversion device, fuel chemical energy into heat energy, and the pot was heated using thermal energy to become hot water having a sufficient quantity and a mass (steam temperature, steam pressure) steam turbine for use. The Anyang City, the power company to my company to buy a split 2 tons of steam condensing gas energy saving factory price steam boiler 20t singapore for supplying electricity demand. The WNS series split condensing boilers using advanced technology designed to greatly improve the thermal efficiency of the boiler, up to about 96%.

The difference between water-tube boilers and fire tube boilers: domestic customers, in fact, to distinguish a fire-tube boilers and water tube boilers are not many, they are more inclined to distinguish between a energy saving factory price steam boiler 20t singapore and hot water boiler, or the difference between fuel and models. But for foreign customers, the focus is different, and in a large number of pot boiler project Zheng exports, the vast majority of customers will distinguish this problem, which is the question of departure from the boiler structure.

A: the adaptability of the gas sources 1: Natural gas must depressurization gas regulator and gas regulator, the pressure before the Burner selected to meet the requirements before entering the burner, in order to work properly. 2: automatic adjustment operation of the boiler performance requirements: since a large gas consumption of the gas boiler, gas boiler as possible in order to reduce impact (sudden pressure regulator after the gas lift system during starting or stopping, sags ), controlling the gas boiler during operation must meet the following requirements: start (1) gas boiler must be adjusted to start at the minimum load of 30% (the rated load); (2) a gas boiler must be gradually reduced before shutdown load, rated load to be reduced before shutdown when the valve closes the solenoid 30%; (3) boilers can be automatically adjusted according to the boiler heat load during normal operation of the actual output stage operating conditions, automatically increasing demand for large Great demand hours automatically reduced, self-sustained heat balance of supply and demand, greatly reducing the number of start and stop the boiler; when reduced to 30% or less of the rated load, heat production is still greater than the output of the boiler, before proceeding down. (According to relevant statistics, the explosion occurred in the gas boiler start-up and shutdown of these two periods that occurred during ignition and fire in., A small gas boiler gas explosion has occurred 2/3 during ignition) (4) is provided above the automatic adjustment function is particularly important when a voltage regulator with many boilers, the boiler can start to avoid pressure fluctuations caused by stopping overpressure safety device or system boiler gas low-voltage protection action, the normal operation of the boiler shutdown. Two: for gas safety, gas boilers must have security facility 1: ignition control system for a gas boiler before ignition, purge the furnace and flue must be carefully excluded combustible gas furnace may be accumulated. A reasonable ignition process control systems to cope with the ignition process is automatically controlled fan only after the completion of furnace cleaning tasks to perform ignition; only when the ignition flame has been established (confirmed by a flame detector), and after a predetermined time has elapsed, a control valve main burner to open; ignition flame is automatically extinguished after a predetermined period of time; when the main flame could not be ignited within a predetermined period of time, the main burner can be automatically and quickly turn off the ignition flame is extinguished while gas boiler ignition procedures are generally monitored and controlled by a program controller. Control of the ignition process, the ignition before the total ventilation should be not less than 3 times the total volume from the furnace to the chimney population. 2: Safety Devices gas boiler is run prevent excessive wind load caused by a low flame, combustion automatic adjustment device should be installed on each boiler, intake air volume and gas supply gas boiler control linkage.

is a professional boiler manufacturer and has more than 70 years of boiler manufacturing history. With the development of the times, Boilers keep up with the trend of the times and constantly introduce new and advanced boilers. Zg provides customers with safe, reliable, high-quality industry and product solutions and related services, builds an integrated information integration platform, focuses on the application fields, capacity selection, project general contracting, and transformation and installation of industrial boilers and power station boilers. Business to meet the different needs of customers' rapid business development.