Heating and hot water daily is an important basis for maintaining the northern region of the normal operation of enterprises; for Legal Daily organs and units, the hot water high efficiency distributor boiler is one of the indispensable energy equipment. Currently, work is facing north Heating equipment and facilities aging, increase energy conservation and environmental protection requirements and other issues. Daily logistics-related legal person responsible for improving the overall level of heating units, and the response advocated by the national energy saving, plans to purchase energy-efficient heating boiler. Considering the increasingly stringent environmental policy, Legal Daily authorities decided to use natural gas as boiler fuel. Fast boiler for 20 years, specializing in the production brand boiler, which had been successfully assisted more than Beijing enterprises and institutions, to provide clean heating. The party technical consultant fast boiler based on actual usage Legal Daily units, providing commercial condensing units 99KW vertical 1 hot water boiler.

Gas-fired steam high efficiency distributor boiler safety valve from installation to use, it must remain vigilant safety valve is one of the most important components of the gas steam boilers, boiler probability of the risk occurring due to various incidents can effectively suppressed. This article focuses on the safety valve from installation to use several important considerations, we do not ignore the use of gas when it steam boiler. A Notes 1 safety valve, the safety valve should be mounted vertically in a high position in the pot business, set box. 2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly. 4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm. 5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve. 6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. 7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve. 8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve. 9, separable economizer outlet, the steam superheater outlet valve must be installed.

The main data processing means is automatically shutdown when the high efficiency distributor boiler pressure is too high, the combustion system will stop working; operating power may also be changed, single-stage or two-stage combustor; can adjust the amount of oil (or gas) to achieve proportional control, whereby depending on the steam pressure adjusting load operation of the burner, to ensure safe operation of the boiler.

2. Environmental policy is required for high efficiency distributor boiler emissions. Coal-fired boilers for waste pollution and energy of the atmosphere is amazing. Many cities have been expressly prohibited by the new economic development zone on the coal-fired boiler, while the use of gas, oil, electric central heating boiler or cogeneration.

3. The boiler is the initial investment, including the boiler unit, ancillary equipment, construction investment and other related costs.