mechanical gas water boiler manufacturers

Comparing the difference between the gas boiler and steam boiler advantages of liquefied gas and steam boilers little difference, that is, different fuels and different fuel consumption, fuel costs used are different. Other gas around almost all the same heating value kcal / cubic, different fuel consumption, fuel costs used are different. The other to see how the quality of boiler manufacturers a straightforward point me to it, natural gas and liquefied petroleum gas boiler boiler boiler is the same, if you buy a natural gas boiler then he can less gas, so no difference in performance , the difference in fuel costs. Gas-fired steam boiler one day fifty-six tons, ban on coal use to increase more than ten tons of biomass is not cost twice as much as natural gas? To natural gas stove or gas boiler steam boiler plant in the case of the same gas production fixed amount of heat per unit time required is equivalent to the boiler. The amount of material converted you born fuel coal heating value in accordance with your heat value of fuel and the raw material. Further, gas steam boilers to burn biomass transformation is required, otherwise the efficiency is not high. Domestic gas boiler manufacturers, how to line brands balance of power? Domestic gas steam boiler manufacturing enterprises, which have considered how brands, the balance of power? Domestic gas steam boiler manufacturing enterprises. The simplest is dosing the water into demineralized water then add precipitator boiler, gas steam boiler how to choose. Dust removal equipment design and selection follow the "advanced technology, economical and practical" principle; reasonable choice of filter design, practical, reliable, advanced, with a smooth operation, good low resistance, low power, cleaning effect, small footprint, etc. features; filter design to achieve low investment, low operating costs. Industry in general regardless of boiler manufacturers are installed, pressure, cook stove, blowpipe these efforts. Most of the owners are determined to suppress and installation team, cook stove, blowpipe program, boiler manufacturers engineers look no problems on the implementation.

Fuel gas boiler automatic instrument sets the control means are included which according to the "industrial boilers Complete supply" and provides fuel gas boiler automated instrument packages supply shall include at least the following: (1) evaporation of 4t / h and 4t / h or less boiler 1 ) detection. Water gauge, vapor pressure gauges (including saturated and superheated), water pressure gauge, water thermometer, thermometer smoke, steam flow rate calculation (including less than evaporation lt / h boiler). Oil temperature, oil pressure, oil level indication, calculates fuel (gas boiler as temperature, pressure, gas), furnace exit gas temperature indication. Evaporation of 4t / h boiler flue gas oxygen content should have, furnace pressure, temperature economizer export indication. 2) regulation. Position of formula (only for non-economizer of the boiler) or continuous feedwater automatic control, automatic adjustment of a combustion boiler the combustion of heavy oil should automatically adjust the oil temperature, air pressure gas boiler there should be automatically adjusted. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. 4) Other. Auxiliary electrical control box, gas boilers should be equipped with explosion-proof electrical control equipment. (2) evaporation of 6t / h and above 6t / h boiler 1) detected. Water gauge, vapor pressure gauges (including superheated saturated), water pressure gauge, water thermometer, thermometer, smoke, water, steam pressure, water pressure indicator, calculated water flow, steam flow indication, recording and computing, oil temperature, oil pressure, oil level indication, indication and calculating the amount of oil (gas boiler as temperature, pressure, gas), economizer inlet and outlet water temperature indication, furnace exit gas temperature, exhaust gas temperature, air pressure, furnace pressure indication, Sheng Mei an inlet, an outlet indicated negative, indicating flue gas oxygen content, there is an outlet air temperature should be indicative of the boiler air preheater, the boiler superheater, there should be recorded and the superheated steam temperature indication. 2) regulation. Continuous automatic adjustment of water supply, drum, induced draft fan damper flap opening remote control, remote pump control valve (an intake gas boiler control valve), a heavy oil combustion boiler should automatically adjust the oil, gas boiler should automatically adjust the air pressure, there is superheater boiler there should automatically adjust the temperature of superheated steam. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over voltage protection and alarm indication of heart steam, oil accident alarm system, furnace flame protection, fuel gas overpressure protection or low temperature alarm and protection. Boiler superheater should have more limited temperature of superheated steam and an alarm indication. 4) control and the other. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.

The use of central heating hot mechanical water boiler manufacturers is the best choice for winter heating in northern China. Shanxi Province is located in Chang Darrow Heating Co., Ltd. mainly provides heating and post-service maintenance of heating equipment, heating clients involved in enterprises and institutions, office buildings, residential housing and a variety of commercial and other entertainment venues. With the wide blue sky covered Battle of the project, China's gradual increase in the proportion of heating for cleaning, heating, Ltd. Dalong Chang respond positively to the call of national policy, high pollution intensity wishing previously used, low thermal efficiency of coal-fired boiler to replace the traditional use hot water boiler clean fuel. After comparing many boiler manufacturers, choosing the optimal selection, determined and professional cooperation parties do fast boiler fuel boiler cleaning equipment. Providing a fast side 35 MW gas tube hot water boiler (SZS35-1.6-Y.Q) according to their actual needs.

Henan combustion control and adjust fast boiler boiler company to introduce small series with the boiler combustion control and adjustment. 1 steam boiler combustion process is the basis of all the work process of the boiler, from the safe operation of the economy, environmental protection point of view, how to properly regulate the burning furnace, saving coal consumption is the responsibility of each fireman. 2 hot mechanical water boiler manufacturers combustion conditions primarily by uniformly supplying the fuel, and air distribution adjusting reasonable combustion equipment is achieved, the coordination of the three, to ensure stable combustion conditions, economy, safety. When coal and boiler load changes, will need to adjust the amount of coal feed and the amount of the wind, in order to obtain a normal combustion conditions. Indicator 3.1 normal combustion conditions 4.8.3 normal combustion means: timely fire burning strong, ash burnout. Specific requirements:. A fuel inlet from the anterior arch 0.1-0.15 m fire, gray ash ex chain at the 0.3-0.4 m burnout. B. fire bed smooth, dense and uniform flame, without flame or blown partial blackening phenomenon. C. Flame intermediate white light, two dark, the fire grate bed length representing more than 3/4 of the effective length. D. pale gray smoke or nearly colorless. In order to achieve good combustion conditions, must maintain a high furnace temperature, the temperature of the upper layer is generally burner combustion layer preferably 1100-1300 deg.] C, may be determined according to the color of the flame. Furnace temperature and flame color relationship in the following table. The outlet temperature of the furnace can also be used to determine, 29MW boiler design furnace outlet temperature of 1017 ℃, 58MW of 998 ℃. 3.3 In the case of normal combustion, the oxygen content in the flue gas is constant, the oximeter, fireman can understand the situation of excess air in the furnace, the furnace excess air is generally mechanical 1.2-1.4%, of excess air and oxygen table below. Ash 3.4 combustibles content is an important sign of good and bad conditions of the boiler combustion, which fuel, combustion equipment, and operations are closely linked, general mechanical furnace ash carbon content should be less than 10%. 3.5 water boiler operation should ensure that in the case of no condensation of the tail to minimize exhaust gas temperature, exhaust gas temperature is controlled at 110-160 ℃. Adjusting and controlling the amount of coal to a fireman who adapt to changes in load, the supply must be based on different types of coal and the various stages of the heating season, the weather trend, the thickness of the seam is determined, the general control of the thickness of 80-100mm low load, medium load control in 100-120mm, high load control in 120-160mm. 2 fireman in specifying a seam thickness, to be due to the furnace, because coal should comprehensive analysis, on balance, for the ash content, water large, large particles, high ash melting point of the coal, generally the appropriate tone thick seam, opposite seam is to tune thin. Small particles of coal or pulverized coal and a low ash melting point of the plurality coal i.e. strong bonding to a thin coal seam. Generally the 3 or the boiler when the load change is not too large, the method should not be used to adjust the thickness of the seam. Because coal seam thickness adjustment can not be effective immediately adjust the load only when a large load changes, and long-term stable operation of the boiler in the new load considering regulating coal seam thickness. 4 seam thickness can be achieved by adjusting the height of the coal and layered coal hopper shutter speed of the drum. Shutter elevation coal, coal may be added into the same hierarchical improved coal hopper drum speed may be increased into the amount of coal seam in order to obtain a proper height, the height of the shutter must coal, coal hopper drum speed stratified and chain speed adjustment of the three. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!