50 hp powerhouse temporary gas or oil steam boiler dealer

So how should a company choose the right boiler?

Determining the right boiler is not a simple matter. After all, there are many aspects involved in purchasing a boiler. This requires communication with various parties such as technical design teams, companies, governments, etc. Here is a brief description of how to choose the right boiler.

1. First, you need to determine the type of boiler (hot water boiler, steam boiler, etc.). Customers can choose the type of boiler according to the application of the boiler, the environment, the company's industry and other information.

2. Capacity. The customer can estimate the boiler capacity based on information such as the environmental area of ​​the boiler application (such as the area where the heating boiler needs heating and the size of the heating boiler).

3. Fuel. The fuel used in the boiler, the boiler that the customer needs to use (biomass, coal, natural gas, oil, etc.), which requires a combination of information.

Recently, Chuzhou City, Anhui Province issued a "Chuzhou Municipal People's Government on the issuance of Chuzhou City to win the Battle of the sky three-year action plan to implement the program," which raised more for coal-fired governance requirements, as follows.

First, the continued implementation of the total coal consumption control. As of 2020, the city's coal accounts for a further decline in the proportion of total energy consumption; the city's coal consumption to complete the tasks assigned by the provincial government; a new coal project implementation reduction of coal instead.

Second, the implementation of the "coal to gas" and "electricity instead of coal." Under the premise of the implementation of the gas source, protect people's livelihood, glass, foundry industry to actively promote natural gas instead of coal gasification project, orderly implementation of coal-fired facilities from coal to gas. Combined with regional and industry energy characteristics, and actively promote the residential electricity, industrial production, building heating heating, transportation, production of five major areas of agricultural implement "electricity instead of coal", focus on improving the proportion of final energy consumption of electricity accounted for.

Third, carry out comprehensive improvement of the boiler. Increase efforts to eliminate small coal-fired boilers, to consolidate the results of coal-fired boilers eliminated. The city basically eliminated 35 tons of steam per hour of coal-fired boilers and furnaces tea, operating the stove, grain storage and drying equipment, coal-fired facilities, no new 35 tons of steam per hour of coal-fired boilers; 35 tons of steam per hour more coal-fired boilers (excluding boiler coal-fired plants) all meet the special emission limit requirements; 65 tons of steam per hour and above all coal-fired boilers and energy-efficient ultra-low emissions to complete the transformation. Low-nitrogen gas boiler substantially complete transformation; urban built-up area of ​​ultra-low emission biomass boilers implement reform.

Fourth, increase the technological transformation efforts cogeneration units to speed up the heating pipe network construction, fully release and improve the heating capacity, eliminate network coverage and bulk coal fired boilers within range. In areas do not have the cogeneration district heating conditions, the existing multiple small coal-fired boilers, alternative construction of large-capacity coal-fired boilers in accordance with the principle of equal volume.

Fifth, strengthen the bulk coal governance. Full implementation of the "Interim Measures for commercial coal quality management" and coal-fired boiler technology standard, good bulk coal use Survey, the development of bulk coal governance implementation. Expand the scope of urban high-pollution fuel combustion zone ban, and gradually extended to the outskirts of the urban area. Combustion zone ban prohibiting the use of high-polluting coal for fuel, the progressive realization of no coal rank. Daly promote quality and new coal stoves, improving combustion efficiency.

1, the boiler ready distal spacing of not less than 2/3 of the length of the furnace, and not less than 2 m; vertical boiler can be shortened; bulk boiler is not less than 4 m, and does not affect the operation and maintenance furnace.

2, the boiler side and rear channel spacing of not less than 0.8 m, and should meet the operational and maintenance (such as replacement tube bundle cleaning, stirring the fire, etc.) requirements.

3, the top horizontal boiler headroom not less than 2 m; vertical boiler top clearance height to facilitate the operation and maintenance; headroom boiler room the other channels, should not be less than 2 meters, when the passage of time and no need to operate its headroom height of 0.7 meters.

4, the boiler room is provided for two or more boilers, the boiler the distance between adjacent cylinder not less than 1.5 times the diameter of the boiler.

5, the boiler room is generally preferred fireman operation chamber provided, on the total rated greater than or equal evaporation 4t / h steam boiler (heating or hot water boiler is equal to or greater than 2.8MW) must be provided stoker operating room. Electric boiler tank may be provided in front of the boiler, and to ensure the art to fireman facing boiler water gauge, pressure gauge and other instruments during operation.

6, total rated evaporation is greater than 2t / h of oil, gas boiler room should be set foam fire extinguisher or water spraying systems, Outdoor proper outdoor fire hydrant, other boiler room should also have fire-fighting equipment.

7, the fuel in the boiler room daily oil tank, the oil pump is generally not located in the boiler room, between daily oil tank, the oil pump between the application of the fire resistance of greater than 2.00h wall, the fire resistance of greater than 1.50h floor spaced from the other parts. Daily fuel tank between the boiler room and the door between the oil pump should be able to self-closing fire doors Class A, and let the oil block measures. Household upper tank return pipe to be provided, should be greater than the oil return pipe back to the oil pump.

8, an oil tank and all piping must have a reliable electrostatic grounding, the grounding resistance should not exceed 30 ohms.

Two of the three types of protection devices What is the difference of fuel vapor 50 hp powerhouse temporary or oil steam boiler dealers and boiler fuel gas steam boiler steam boiler fuel for steam boilers, steam boilers or fuel oil-fired boiler is in, no matter which argument, are refers to this kind of boiler fuel steam boiler. 1. the type of fuel steam boiler fuel steam boiler, which in general, can be divided into both established and horizontal. Vertical fuel steam boiler: the combustion engine, generally use the set in this manner, and using two-pass configuration, so that complete combustion can be performed. In addition, the use of these forms, the stability of the operation of the boiler, it is also very beneficial. The advantages of vertical steam boiler fuel, mainly for high thermal efficiency, and can reduce costs. Horizontal fuel steam boiler: the structure, using a three-pass tube pyrotechnic this configuration, pressurized combustion chamber so that combustion, thereby reducing the combustion load, and reduce exhaust gas temperature. As a result, promote energy conservation, economic performance of the boiler. Further, since the waveform of threaded pipe and furnace thermal efficiency of the boiler can be remarkably improved, and the use of time can be increased. 2. The fuel vapor pressure protection boiler controller: generally this type of high sensitivity, is mainly Zidongkongzhi or chain protection. And may be adjusted according to actual operating pressure of the boiler, so that appropriate. Flame protection: in the main burner, a flame failure protection devices. Its role is the amount of fuel steam boiler combustion is detected, when abnormal combustion, can take immediate steps to make the boiler stopped working in order to avoid some of the adverse consequences. Self-locking power failure protection: Usually burst power for this case the use of the protective device, so that when a sudden power failure, the fuel steam boilers can immediately shutdown and self-locking. Note, however, that when power is restored, the boiler will not start on its own, it must be reset after unlock, boiler to start the ignition and start working. Fuel gas steam boiler and the steam boiler distinction fuel gas steam boiler and a steam boiler, as energy saving device belong to the combustion products of carbon dioxide and water, will not pollute the environment. Oil-fired boiler and gas boiler biggest difference is the use of different fuels, gas boilers use natural gas, city gas as the fuel, light oil, heavy oil-fired boiler is used as fuel. In contrast gas boilers, boiler fuel cost is much higher than gas boilers, therefore, those commonly used in the oil-fired boiler operating conditions of enterprises do not have a gas boiler or Shiyedanwei use. The difference between the fuel and gas steam boiler steam boiler: 1, fuel different: the former light oil, heavy oil as a fuel, which uses natural gas, city gas, liquefied petroleum gas as fuel. 2, the burner different: the former use of oil burners, gas burners later use. 3, different cost: the former high cost, about 1-2 times the cost of the latter. The same point of the fuel gas steam boiler and a steam boiler: 1, the same boiler: the same tonnage same steam boiler or hot water boiler of the boiler body. 2, the same auxiliary components: in addition to the burner, auxiliary oil-fired boiler and gas boiler accessories equivalent tonnage same. 3, the same production process: The process of production and processing were carried out in accordance with the same process and production standards.