2t steam boiler Price Cambodia

1, after receiving the task given row, PPE dressed, F bring special wrench, open the given row situ total gate.

2, once the door fully open, contact fireman DCS screen to open the corresponding electric door sewage, sewage finished, first off the secondary door, shut the door once, by-road in turn. All sewage finished, close the door once each sewage and sewage total gate

3, sewage, should pay close attention to the water level, the water level there is any abnormal or accident, they should stop the discharge operation.

4, sewage two hours, you should check whether each door core doors sewage leakage, such as leakage should quickly open the door once the sewage to drain the possible residue stuck in the door at the core, the same before the operation to contact and obtain consent boiler management .

Heating Area:

When the heating of buildings, heating area is also one of the issues to be considered, the size of the heating area directly affects the choice of boiler capacity. For heating area, fast boiler technician summed up the relationship equation heating boiler heating volume and area.

Shanxi Province to respond positively to treatment advice on remediation since 2014, new registrations of 10 steam tons / hour coal-fired boilers and environmental supervision of the central group feedback, recently, government inspectors focus group, conducted a comprehensive inspection of coal-fired boilers activities, to grasp the progress and corrective measures to ensure the successful completion of the renovation work.

The statistics, since 2014, Datong new registered 10 steam tons / hour and a total of 48 coal-fired boilers, according to the provincial Bureau of Quality Supervision requirements, the county district special equipment related regulatory authorities have the 48 legally registered boilers Log off, and conduct regular inspections. As of to date, 36 units have been removed, still with 11 units, the remaining aspects of the transformation of a substance being born.

Currently, 11 boilers are still in use, some have been re-ordered natural gas boiler, gas pipeline work underway access; some have been able to replace air heating equipment; also because of the administrative division adjustment, need to further define the charge of the task.

Follow-up inspection staff proposed remediation work boiler suggested that there was any objection to the main regulatory responsibility, clear as soon as possible; dismantled boiler, strengthen follow-up supervision; boilers still in use, depending on the circumstances be accountable to county-owned enterprises; the ongoing transformation of the boiler, a clear transformation is complete to confirm compliance and acceptance of responsibility department, and follow-up supervision.

How to treat boiler waste water

During the long-term operation of boiler, the water treatment equipment will inevitably aging. When the equipment is in abnormal operation, the pollution density of the water supply is larger, and there is a certain amount of sediment in the water supply process. When the water with sediment component evaporates in the boiler and more sediment materials are precipitated, the boiler pipe will be blocked, the heat dissipation effect will be poor, and the probability of tube burst will occur. The formation of boiler slag will clog the furnace tube and cause tube explosion if it is not discharged out of the furnace at regular intervals. At the same time, it also reduces the heat transfer effect.