Low Price Commercial 2t gas steam boiler Vietnam

Process safety valve check valve gas low price commercial 2t steam boiler vietnam is one of the three safety accessories gas steam boiler, when the boiler pressure is too high, the pressure relief valve will automatically exhaust, gas steam boiler is the important safety equipment . The case of a new installation, overhaul, lack of consumer safety valve shutdown and restart more than three consecutive months, have had to re-check safety valve, safety valve to ensure accurate and reliable by the company safety officer, boiler technician, run operators, maintenance personnel together with the completion of the adjustment. Valve adjustment procedure is as follows: 1, the steam boiler when the gas vapor pressure close to the operating pressure of the safety valve, and retest check valve to the air motor exhaust, drainage accident flexibility and reliability of the electric valve, and the panel reinspection situ pressure gauge, the water level of accuracy, such as failure, not allowed to heat the school. 2, ready to call and check the quality of communication tools, a signal indicating whether the good. 3, adjust the safety valves, boiler pressure should be kept stable, pay attention to monitoring gas steam boiler drum level, and maintain normal. 4, steam boiler safety valve to adjust the pressure gauge in place of instructions shall prevail. If necessary using 0.4 or more for the accuracy of the gauge. 5, adjust the safety valve should be carried out only by descending. It should checksum gas steam boiler tuning high pressure safety valve, after the school seizure of the entire set of low pressure relief valve. 6, the following should be in the 0.3MPa, the movement preventing measures must do a good job of setting relatively low pressure steam boiler safety valve safety valve before adjusting. 7, by combustion, and exhaust steam adjust the degree of opening to the air slowly and smoothly up to the required setting pressure. 8, when the gas pressure steam boiler safety valve set pressure to rise if action is normal, then the action and reseating pressure values ​​recorded. If action is not correct or not action should be immediately opened to the air exhaust valve, while the combustion boiler weakened, stop boost, and buck 0.3MPa or less, re-adjust the boiler technician as required by maintenance personnel, until the compliance date. (Lead or lag 0.05MPa action is normal). 9, after the completion valve to adjust gas steam boiler, boiler 0.3MPa or less down to the lifting device and can be installed and fastened to the protective cover, a braking measure required under check valve removal, then Articles 7, 8 verify until all required safety valve calibration check is completed. 10, the safety valve to adjust the gas boiler, check the results recorded in the "safety valve to adjust the recording Visa" within the participants should verify the signatures and Internet safety valve input to the corresponding data in the ledger. During operation gas steam boiler, not only to regularly check on the safety valve, at the same time, we must regularly monitor boiler inspection to ensure that the boiler fully meet the safety requirements!

Water produced by the following factors: the temperature of the flue gas (91% in order to achieve thermal efficiency, the temperature of the flue gas needed to reach 170 ℃), where the total surface area of ​​the heat chimney, chimney and chimney material. Maintenance of the burner. Electric low price commercial 2t steam boiler vietnam and burner maintenance, repair after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion in the boiler memory stay too long. 3, clean electric boiler essential content.

The design of the boiler room fire interval is how much? Section 13.1.1 boiler fire hazard classification and fire rating should meet the following requirements: a room, boiler production plant belongs to class D, to the low price commercial 2t steam boiler vietnam rated evaporation 4t / h, when the hot water boiler rated output is greater than 2.8MW, boiler room building fire resistance rating of not less than two; steam boiler equal to or less than the rated evaporation 4t / h, when the hot water boiler is equal to or less than the rated output 2.8MW, between the boiler building fire resistance rating of not less than three; II. when the inter-tank, and a pump room between the oil heater are class C production plant, its construction fire resistance rating of not less than two, disposed within said room between the auxiliary boiler room, a room should be set apart from other firewall; III. between the gas regulator production plant belonging to Group a, which is not less than two building fire rating, should be provided between the boiler room and the immediate neighborhood regulator firewall spaced boiler room, which doors open outwards and should not be passed directly the boiler room, the ground should not spark floor. Referring again to the provisions of Article 5.2.2 GB50016-2006 "architectural design code for fire protection," according to fire resistance rating.

On the ISH heating HVAC industry event, fast Boiler bring new products customized for the paper and packaging industry well-built --- Euromonitor θ5 stunning debut, attracting various participants competing concerns. The product closed condensate recovery system, temperature condensate directly into the boiler design, three-pass boiler with economizer + + structure air preheater for recycling heat from the high temperature condensed water source, the thermal efficiency of up to 95%, to save operating costs with immediate effect.