100ton Water gas boiler in Germany

Further, the sulfur content of natural gas is also very small, and the coal-fired boiler dust removal, desulfurization, denitrification had on the gas boiler need only consider the problem of denitrification. 3, from the point of view of other waste emissions, natural gas, almost no other pollutants, especially in urban gas; and coal, then coal field (especially small boiler mostly built on open air) during the rainy season will produce slime water into groundwater import or surface water, after burning ash transport will produce dust. 4, of course, there are differences from other areas, for small boilers for gas-fired boiler energy efficiency is higher than a lot of coal-fired boilers, process equipment is simple, small footprint, low cost of operation and maintenance and so on.

The main reason gas steam boiler produces smoke which fuel gas steam boiler main cause of smoke. A fuel gas steam boiler: oil, gas oil quality is not good when the gas contains more water, reduce the heat value of the fuel, while producing steam, the furnace temperature tends to decrease, making it difficult to burn, easy to produce smoke. Water and more oil, mainly when unloading rain water into the oil during heating the oil in water vapor penetration. When the oil contains impurities, the impurities unburned produce fine coke, the coke into fine smoke, dust becomes large, and the formation of soot. Impurities contained in the oil and gas, but also affect the pure oil and pure combustion gas generated soot. Oil impurities, mainly due to inappropriate choice of filters or filter difference impurity removal effect. Second, the failure of the fuel atomizing nozzle member main burner fuel oil atomizing nozzle. Atomizing oil burner nozzle fails, affecting the quality of the atomization, easy to poor combustion. 1, the adhesiveness between the bonding surface of the oil and the consequences of failure oil atomizers swirl atomizers and the splitter plate well, leakage will occur, atomized large oil particles, increasing the amount of fuel injection and the like. In this case serious deterioration of the quality of the combustion, the oil droplets have landed on the water wall, stacking up oil coke, partially unburned black smoke into droplets. The tangential swirl chip groove clogging mist causes uneven density distribution in the dense side of the oil mist, combustion air be insufficient. In the more dilute side of the oil mist, combustion air causes severe local excess. Mixed with oil, wind conditions deteriorated significantly, combustion conditions deteriorate, resulting in black smoke. 2, spray atomization slice failure and the consequences of failure to clogging and wear. Nozzle clogging, resulting in blockage of the fuel injection quantity is not glib increase, oil particle size thicker, the effect of fuel poor and black smoke. Wear injection port, a large hole diameter, increasing the amount of fuel injection, increasing the particle size of oil affect combustion efficiency, produce black smoke. The use of artificial gas burner, naphthalene and tar and other impurities will block the nozzles, the influence of gas distribution, resulting in black smoke. Should therefore be cleaned regularly, or clogging of the selected burner. 3, the partition partitioning poor poor, insufficient supply of air into and excess. The amount of air can not meet the requirements of the fuel combustion, so that combustion of fuel can not be sufficiently black smoke. The amount of air, will result in lower combustion temperature, black smoke and fuel difficult to burn. 4, the furnace temperature is too low when starting the furnace, fuel oil steam boiler furnace temperature is too low due to easy black smoke. 5, the furnace hearth product oil is sometimes caused by internal combustion nozzle oil accumulated inside the chamber, the oil reservoir coke black smoke at high temperature. Causes dripping of fuel combustion nozzle: ① The drip just work, just at the operating pressure is too low, the oil will flow from the nozzle, instead of the discharge. The reason for low oil pressure is a solenoid valve, the valve is clogged filter or the like or failure caused by contamination. ② In the dripping process work, probably because the relative position of burner nozzle mounting head too far, improper ignition electrode position, the oil into the atomizer, the nozzle holder is mounted is not tight, nozzle dirty, low oil pressure caused. ③ When the dripping stopped, because the line between the pump and the air nozzle, electromagnetic valve or a hydraulic valve or dirty failure. 6, the furnace flue purged countless consequences when the furnace flue remnants of oil and gas, when gas purging endless, high temperatures encountered in the explosion and black smoke. 7, the furnace smoke, sparks, the furnace pressure is too ①; ② inappropriate choice of the burner, the burner flame is too long or too much power; ③ improper combustion ratio, there are more to produce products of incomplete combustion; ④ atomization quality is not good nozzle or improper installation location, or affect the combustion flame into the furnace off port; ⑤ flue is blocked, poor smoke; ⑥ a secondary air mismatches; irrational ⑦ furnace structure; ⑧ oil spray angle is selected from with improper.

Everyone has an understanding of the principles and methods of using hot 100ton water boiler in germanys. The editor is not introduced to everyone. However, if you are interested in hot water boilers, the editor can give you some knowledge of their performance. Let's look at the advantages of the hot water boiler in use. Low investment and operating costs: biomass combustion mechanism is well designed. The conversion cost is low when used in all kinds of equipment. Compared with the heating cost of fuel boiler, the operating cost is reduced by more than 60%, and the heating cost of gas-fired boiler is reduced by more than 40%. It is an electric furnace and an oil stove. The choice of energy saving and environmental protection transformation and upgrading of gas furnace. Simple operation, dimension Protection convenience: frequency conversion automatic feeding, air and ash removal, simple operation, small workload, duty personnel, biomass burners are the choice of most boiler enterprises. A wide range of fuel sources: the burner uses wood and wood particles as raw materials, high calorific value, to avoid the coking phenomenon of straw particles. The hot water boiler has the obvious environmental benefit, the hot water boiler has no pollution, has the obvious environmental benefit: uses the renewable biomass energy as the fuel, realizes the sustainable energy utilization. The low emission of NOX,SO2 and dust in flue gas of high temperature subsection combustion technology is a substitute for fuel (gas) burner and electric heating. Non-tar, Waste water and other waste discharge: using high temperature pyrolysis combustion technology, tar and other gaseous direct combustion, solved the technical problem of high biomass gasification tar content, and avoided the secondary pollution of water quality caused by washing tar. High heating temperature: this technology uses secondary air distribution, furnace pressure for 500-700mm water column, to ensure normal fluidization in the injection zone. Continuous feed continuous production, flame stability, high temperature up to 1300 ℃, has been widely used in industry. Therefore, hot water boiler has many advantages. I hope to make full use of the performance of the hot water boiler in the process of operation.

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two boilers work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.