4t coal steam boiler Best Selling Georgia

Coal to natural gas operations bunch of factors that vertical pressure 4t coal steam boiler best selling georgia energy consumption indicators of the country are carried out in a big way, the choice of vertical steam boiler, to a large extent minus the pollution of powder, together with nitrogen oxides and other dangerous gases the press has been discharged. Energy consumption indicators is an important rule to measure vertical steam boiler, to discuss the next bunch of factors under pressure vertical steam boiler energy consumption indicators. By analyzing the relevant departments, vertical steam boiler heat loss occurs mainly includes two aspects: the proportion of non-standard sufficient combustion air with exhaust heat loss. Weaken the heat loss can be retrofitted in the vertical steam boiler chimney terminal latent heat of re-use form, or in the selection of better boiler system FGR. Combustion air ratio is not sufficiently decomposed inappropriate criteria: ordinary vertical ejector-type steam boiler burner based, air-fuel ratio can not be formed in the active mobilization. More vertical steam boiler based on a mechanical blower burner, air-fuel ratio due to the following standards several factors: air-fuel ratio standard comprises two situations: when oxygen is excessive, the excess will be an infinite cryogenic air by heat conduction, caused by rising energy vertical steam boilers, low energy consumption vertical steam boiler index; when there is insufficient oxygen, there will not be sufficient to ignite the situation, leading to low energy consumption indicators vertical steam boiler.

China Association of boiler and boiler water treatment boiler technology plays in the development of healthy and clean technology development and lead the industry in an important position, and boiler manufacturers are inseparable, in the future, the Group will soon square to maintain good communication with the Association to promote the technological innovation industry, enhance the technological level of the industry, promote the vigorous development of the boiler industry to contribute their efforts.

About six tons of 4t coal steam boiler best selling georgia shutdown of a temporary shutdown: It is planned, therefore slow cooling during shutdown protection device, it should also pay attention to safety, pause furnace according to the rules in Chapter IV Fenghuo (pressure fire) get on. 2, safety shutdown: care should be completely stopped even on normal operation plan for 1 to 3 months to be a shutdown, shutdown should maintain more safety injection apparatus, after the shutdown, and other water-cooled furnace to below 70 ℃ when they let go of the gas, open manholes, hand holes, rinse the pot with water scale. 3, emergency shutdown: the boiler operation, when the case of the following circumstances, should an emergency shutdown, and notify the relevant authorities. (1) expanding the cease-fire should first see if the water table level is called to take water law. If Inception water table, water cock side, and then close the steam cock, and then turn on the water faucet open and close repeatedly called after water, still can not see the water. (2) All water supply equipment failure. (3) All water gauge, pressure gauge, safety one of all the failures. (4) a boiler or furnace wall element damage, serious threat to the safe operation of the boiler, emergency shutdown, should focus on preventing the stop of the accident and the specific steps as follows: ① first blowing off; ② the coal on the grate red raking; ③ Close induced draft fan.

How to provide boiler thermal efficiency thermal efficiency of the 4t coal steam boiler best selling georgia has the following methods: low-pressure boiler at the factory has been designed considering the problem of thermal efficiency of the boiler, the flue gas from the device or change little aspects of energy-saving possibilities, it is best to start from the energy-saving operation (here talk recovered water vapor condensation method). The current design thermal efficiency of domestic low-pressure boiler is generally 70 to 90%, generally the actual operation of the thermal efficiency of about 60 to 80%, some even below 50%, a small low pressure industry as long as the operation, maintenance properly, can meet the design thermal efficiency of manufacturers. I think the management and operation should pay attention to the following points: First, the boiler flue gas temperature monitoring. Typically the maximum exhaust heat loss is loss, it is important to good control of exhaust gas temperature, exhaust gas temperature is generally low pressure coal-fired boiler of 150 ~ 180 ℃, fuel boiler exhaust gas temperature is 210 ~ 240 ℃, so when the boiler to find out why when the exhaust temperature is too high and promptly eliminated. Coal-fired boiler flue gas temperature is too high reasons are: high furnace pressure; shorting smoke; thick soot on the heat pipe; thick scale pot like. High temperature fuel exhaust reasons are: 1 air not adjusted oil, the oil is not completely burned in the chimney the secondary combustion occurs aft; 2 soot too, the need for timely cleaning; 3 shorting smoke; 4.... thick scale; Second, controlling blowdown rate. Without restricting the general rate of industrial sewage control in 5 to 10%, in the pot of water to ensure that qualified (mainly total alkalinity and pH value), the blowdown rate as low as possible, the sewage to adhere to the "ground row, row less, are ranked "the rules. Third, the maintenance of good furnace wall insulation. The heat loss is also a relatively large heat losses, now the manufacturers in the manufacturing and design has been well thought out, so we do not need to change, we just trying to be difficult to maintain. Outer surface temperature generally does not exceed 50 ℃, it will have to find out the reasons such as too high, and remove. Boiler insulation should always be kept dry, for coal, not a long positive run, or easy to damage the coal furnace wall and gate and so on. Fourth, adjust the ratio of fuel and air volume, complete combustion of the fuel as possible. Generally do not have a small amount of wind testing instruments, we can only go by experience adjustment. For oil, the normal combustion flame was yellow-white, non-glare, flame stability, no visible smoke chimney; For coal, the normal combustion flame pale, no visible smoke chimney, basic cinder burn coal particles as even as possible. Fifth, the need for a sound water treatment. Improve water treatment and water quality testing can maximize prevent fouling and correct guidance of the sewage, but it did not do a lot of small, companies usually do not pay attention.