boilers de gas precios

Problems coal boilers de precios gas boiler gas coal problems are: 1, more coal ash, 2, unevenness of coal particles, 3, coal contains a large amount of impurities, 4, a lower heating value of coal, 5 when combustion is not easy to ignite fire, 6, coal moisture content uncertain. 7, does not burn coal, slag high carbon content. In general, use is preferably designed coal boiler design coal or coal close, in order to ensure stable combustion. In recent years due to the growing tension surrounding the coal supply, coal supply has become diversified, coal quality is very different than before coal, have a great impact on the stability of the boiler combustion and normal heating operation. Impact of coal combustion boiler stable for: calorific value of coal is coal reflects an important indicator of good or bad, when the low calorific value of coal to a certain value, will not only affect the incomplete combustion instability and can lead boiler flameout, the outlet temperature of the boiler is difficult to compliance, affecting the normal operation. Volatile combustion and can be deposited at lower temperatures, as the combustion heat, the temperature rapidly increased coke particles, provide an extremely favorable conditions for ignition and combustion, volatiles further increased coke deposition and internal voids and the external reaction area, will help improve the speed of burning coke. Thus, the greater the content of volatile, nonflammable, the less fixed carbon in the coal component, the easier coal burning ember, devolatilization of many voids, increases the surface area of ​​the reaction, the combustion reaction is accelerated. When the volatile content is reduced, pulverized coal ignition temperature significantly increased, the hot increases, difficult fire, ignition time required becomes longer, the combustion stability is reduced, shifting the center of the flame, furnace absorbed radiation heating surface reduce heat, increase the heat absorption of the convection heating surface, the rear exhaust temperature, exhaust loss increases.

Fast boilers de precios is a very trustworthy business, whether it is the beginning of cooperation or boiler put into operation, such as a party soon have maintained cooperative attitude, patience, careful. To ensure long-term stability of the latter part of the boiler operation, fast boiler technician fireman's gave us a free people to do the training, precautions and reduce the accident rate method full guidance boiler operation. --customer feedback

[6], oil-fired boilers de precios, must configure a more complex fuel system (especially the combustion of heavy oil, while residue), such as tanks, pumps, filters, heat pipes, etc., must occupy a certain space, and gas boilers, then No configuration caisson. The access network can simply supply gas conduit, of course, need to set the pressure regulating means and a solenoid valve on the pipe, valve accessories cushion so as to ensure safe operation of the boiler.

Master these techniques can prolong the life of your boilers de precios low nitrogen, is determined not to look at it: low-nitrogen boiler is in obvious advantages on the basis of environmental policy and saving money on, are widely used. But there are many business units are new low nitrogen boiler, for how to operate properly and prolong the life of the boiler, and not very good grasp. Fast boiler professional production of low nitrogen boiler, summarizes the following three extend boiler life low nitrogen tips to help users better operating low nitrogen boiler. 1, low nitrogen good power boiler inspection work is the driving force of energy in industrial production, before use, you must first do a good job security and troubleshooting, power checks and maintenance work, in order to ensure the safety of high-speed operation and boiler operator; in addition , but also on the part of a full range of equipment and inspection work, to make the life of low nitrogen boiler becomes longer. 2, the holding device periodically to check whether dried and smoke when a low nitrogen boiler tube patency after completion, the operator should be promptly cut off the power, and when the apparatus until the temperature drops, dust and dirt need to clean the housing, but also to boiler placed in a dry and ventilated place, the next device in order to ensure the normally open, secondly, due to the low nitrogen boiler exhaust gas is carried out primarily by the threaded pipe, so that the operator using this device, after completion, then periodically cleaning the smoke pipe, to avoid being blocked by dust and affect their effectiveness. 3, regularly adding parts in time to make the right judgments and processing lubricants low nitrogen boiler in the low load operation, the supervisory inspector must concentrate on strengthening the analysis of each instrument, abnormal situation, in order to ensure the boiler normal operation and prolong its service life; in addition, also regularly add the oil to low nitrogen in various parts of the boiler, the boiler can reduce the running resistance, improve production efficiency.