boiler Fully Automatic 6 ton Commercial Jordan

Food factory operating costs Steam Boiler: food plant steam operating cost boiler fully automatic 6 ton commercial jordan analysis, including the sum of the electricity, natural gas costs, demineralized water (dose), labor costs and other costs required for the principle of conservation of the energy, the thermal efficiency of the boiler calculation is running at full capacity 97.94% . (1) The natural gas fuel heating value: Qdw = 8500 kcal / Nm3 = consumption of natural gas production of 2 tons of steam heat (heat value gas boiler thermal efficiency x) = 2,60,104kCal / h (8500kCal / Nm, 97.94%), 144.1 nm / h, and then consider the practical use of heat loss of about 3.8%, such as heat and water. A = 144.1 / (1-3.8%) = Cost 149.75,150Nm3 / h of gas per hour is run B = 150nm / h, 4.387 yuan / Nm (Yantai Industrial gas prices) 658 yuan / hr.

Henan gas boiler fully automatic 6 ton commercial jordan condensing gas boiler 1. The working principle of the gas boiler operation principle of the gas boiler is natural gas, liquefied petroleum gas, fuel gas such as city gas as fuel, the amount released by burning in a furnace, to heat water in the boiler, and which is vaporized into steam energy conversion device. Principle: water drum is continuously released from the combustion of a gaseous fuel energy to heat the furnace, raising the temperature and generating steam under pressure, since the boiling point of water increases with increasing pressure, the pan is sealed, in which water vapor limited expansion of the pressure generated by forming a heat power (strictly speaking, water vapor in the boiler drum is heated to the constant-pressure saturated water formed regasified) is widely used as an energy source. 2.Henan condensing gas boiler working principle condensing gas boiler is the working principle of the device through a certain heat boiler combustion flue gas emissions (typically at about 140 deg.] C) for recovery of energy, the exhaust gas temperature after recovery only about 60 ℃, so improving the thermal efficiency of about 10%, naturally it saves about 10% of the gas; while the energy recovery process, but also possible to reduce harmful emissions, reduce environmental pollution. 3. A gas boiler steam and boiler works Henan condensing gas compared to the traditional boiler, the exhaust gas temperature is generally 160 ~ 250 ℃, or even higher, such that combustion of the fuel produced when water is overheated in the flue gas with the smoke. gas losses through the chimney, the conventional heat efficiency of the boiler is generally only 85% to 91%. Henan condensing boiler and the flue gas temperature is reduced to 50 ~ 70 ℃, full recovery of the latent heat sensible heat of flue gas and steam, the highest thermal efficiency of up to 109%, and therefore very energy efficient. These are the gas boilers and gas condensing boiler works in Henan, the popular terms, is the use of natural gas-fired boiler to heat the water to warm or radiator heating. The condensing gas boiler condensate using the most advanced technology, it can be recycled again using the hot flue gas, it is very energy efficient.

Clear oil-fired boiler fully automatic 6 ton commercial jordan pressure gauge: pressure gauge is displayed in the oil-fired boiler media is the main safety accessories boiler boiler operator in the operation closely watched. Pressure gauge not only to check regularly transferred to the metering sector, but also in the boiler operation, done regularly to gauge back to zero test, to verify the reliability of the sensitive pressure gauge to ensure the safe operation of the boiler. Procedure: (1) gauge twisted way cock closed trap passage, the air passage is opened and the pressure gauge; gauge the pressure relief, the pointer back to zero; if (2) Check the pointer back gauge to zero limiting, the staple; (3) back to zero if limiting, nails, pressure gauges should twisting three-way valve, pressure gauge and close the air passage, slowly open the trap passage and the pressure gauge, the fuel gauge is displayed pressure in the boiler; (4) if the pointer can not return to zero (including a staple stop finite and infinite stopper nails), the pointer should be checked from the zero bit value exceeds a predetermined tolerance gauge; (5) exceeds a predetermined pressure gauge allows error, the pressure gauge should be replaced; (6) If the gauge does not exceed the predetermined allowable error, considered acceptable, the pressure gauge should twist way cock, pressure gauge and close the air passage, slowly open the trap passage and the pressure gauge , pressure gauge immediately displayed in the oil-fired boiler. Oil-fired boiler pressure gauge siphon flushing operation

Provide for the growers Kingenta Ecological Engineering Group, the main compound fertilizer, slow release fertilizer, water soluble fertilizer, bio-fertilizer, soil conditioner, etc. required for a full line of soil and - with another giant fertilizer industry enterprises farming solutions services. 2016, Kim Jong large group with my company, to buy one of two 10 tons of steam condensing steam boiler fully automatic 6 ton commercial jordan (WNS10-1.25-Y.Q). It is the product side were quick constant pursuit of quality, in-depth research and development of control and intelligent control, boiler energy efficiency as well as high demand for continuous improvement of energy efficiency and emissions, making the fertilizer industry's two leading companies invariably choose the fast way hand in hand!