factory Dealer price hot sale gas steam boiler

Check gas boiler before the preparation of cease-fire and that the flue slow cooling drum; open all manholes and hand holes in the header of the boiler body; let go of the gas within the boiler drum and water; the boiler combustion chamber, drum , flue ducts thorough cleaning; steam pipeline cleaning and removing rust and scale water; repair or replace a manhole cover; ready safelight, flashlights, test rods, tools and the like. Burner gas is an important part of the boiler, the main control system and combustion system components, the problem lies in easy control cabinet, 1. However, the normal ignition off this failure phenomenon typical cause of several tens of seconds after the self-ignition of the burner flame sensor dirty parts. The flame sensor is a photoresistor when irradiated with light of its own resistance decreases resistance value increases as a state of high impedance low impedance state when the light irradiation. Burner flame sensor controller in accordance with a resistance value to determine whether the process is continued if the combustion stop combustion flame sensor high impedance supply is immediately stopped to prevent the unburned diesel fuel reservoir. Flame sensor probe positioned within the burner duct, since the black smoke, tempering, blowing dust and other reasons that the surface thus losing readily soiling the photosensitive functionality. Check sensor probe, its surface is cleaned with a detergent or alcohol, if necessary. 2. Ignition normal exhaust smoke color but not normal diesel fuel injected into the burner is burning the mixture under stirring, when the appropriate amount of blowing water vapor and CO2 exhaust gas atomization are colorless. When there is insufficient air supply can cause incomplete combustion of diesel soot to form CO and thus give rise to the phenomenon of black smoke exhaust. However, if a strong wind inlet excessive combustion of oil mist may be blown off too late will form white smoke is discharged. Common causes of black smoke exhaust of combustion into the throttle opening is too small, white smoke into the throttle opening is reason to see through the large, two cases should be re-adjusted into the throttle. Exhaust smoke color can be observed while the side damper opening degree until near colorless in exhaust smoke color adjustment. Another reason is that black smoke exhaust poor atomization of diesel, oil mist contained in the larger droplets, can not be sufficiently mixed with the air due to a local incomplete combustion produce soot.

Fuel gas control step and the blowing process air volume of the total fuel gas factory dealer price hot sale steam boiler steam boiler is achieved by adjusting a liquid coupling scoop blower. Organization fuel gas steam boiler combustion, is to make a, air pressure, air flow of secondary air with the good. Adjusting the amount of primary air should meet it carries the fuel into the furnace ignition of volatile oxygen required, and to maintain a certain speed, and without clogging the fuel discharge pipe of the jet having a certain rigidity. Primary air volume is too large and too small, the wind speed is too high and too low, should be avoided. In addition to adjusting the secondary air of combustion of the fuel should ensure that the oxygen demand, but must maintain a certain wind speed and primary air is mixed with the master time should have a strong stirring and mixing coke penetrate "the Gray" kinetic , which requires the case may be, each layer of the secondary air flow rate, in order to achieve stable combustion and flue gas excess oxygen appropriate destination. Fuel gas steam boiler, secondary air with what is better? Primary air volume air volume of the total share is called the primary air rate. A small air fraction, pulverized coal is heated to at least the heat required for the ignition point, fire faster, but the amount of primary air to satisfy the principle of combustion of volatiles. Secondary air mixed with the primary air time to the right. If it is mixed before ignition, means an increase in the amount of primary air, so that the ignition delay; hypoxia combustion secondary air if mixed will make late after ignition; if secondary air is mixed all at one position, since the secondary air temperature well below flame temperature, the flame temperature decreases, the combustion slows down, causing the fire. Therefore, the secondary air mixed with fuel should be based on the nature of the combustion zone as required timely sent, so that the combustion of oxygen, and will not reduce the flame temperature to ensure complete combustion and ignition stability. One or two wind speed with what is better? Fuel gas steam boiler once the wind speed is high, the fuel gas stream will catch fire in places far away from the burner, the ignition point postponed; once the wind speed is too low, it will cause a blocked ducts, and ignition point is too far forward, the burner will burn , but also easy to coke near the burner.

To complete the "clean winter heating pilot cities in northern areas," the goals and tasks, Jinan Municipal People's Government issued the "Jinan City" pilot cities for winter heating cleaning northern "three-year implementation plan (2017-2020 years)." "Program" is mentioned, three-year pilot period 59 key projects a total investment of 27.3 billion yuan, 2.1 billion yuan from the central government funds, municipal funds 5.8 billion yuan financial support to attract social capital of 19.4 billion yuan. Six technical work in accordance with the deployment path, focusing on elimination of coal-fired boilers, clean the deep geothermal heating, urban and rural construction and other clean energy alternative to lead technical projects, improve the maintenance of post-operation, promote clean winter heating work in an orderly manner.

Focus on the implementation of urban and rural clean energy alternatives. In the vast rural areas and central heating uncovered areas, in accordance with the enterprise-based, government promotion, residents affordable policy, local conditions, the use of alternative energy classification implementation. Urban and rural clean energy alternative to task a total of 48 projects, plans a total investment of 6.272 billion yuan (excluding clean coal-burning alternative to low-quality coal project), in which the central budget funds 820 million yuan, local financial and social capital invested 5.452 billion yuan. Coal to electricity which involves 19 projects, the use of alternative energy, Valley Electric energy storage, energy management contract, support clean green electricity for heating, with a total investment of 650 million yuan, of which the use of the central budget funds 250 million yuan; shed no change change clean heating, involving 95 000, in which the central government 200 million yuan.

We need boilers for central heating urgently. When it get cold, we need a lot of high pressure boilers for central heating. To meet your requirements, our ZG Boiler new type gas fired factory dealer price hot sale steam boilers have launched to the global market. This WNS natural gas Fired Boiler adopts new technology developed by our ZG engineers. And this boiler adopts three pass design and spiral fin tube to enhance its heating efficiency. WNS series Condensing Boiler with Advanced technologies cooperated with German company are introduced into the WNS fire tube gas & oil fired steam boilers.