gas boiler izmir

1, the safety valve should be mounted vertically in a high position in the pot business, set box.

2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve.

3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly.

4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm.

5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve.

6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust.

7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve.

8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve.

Three kinds of ventilation boiler izmirs often used at runtime to be continuously supplied to the boiler the combustion air required, and the resulting flue gas continuously drawn, a process called draft process of the boiler. Once the venting is stopped, the boiler will stop running; usually mechanically ventilated, i.e., by means of a pressure head generated by the fan to overcome smoke flow resistance of the duct. Mechanical ventilation currently used in the following three. A negative pressure ventilation chimney addition to using, the former also mounted chimney draft fan to overcome the resistance of all of the smoke, the air duct. This small capacity of ventilation, smoke wind resistance is not so large boiler system is more applicable. Second, while a balanced draft and induced draft fan blower mounted in the boiler smoke, air system. Port to the suction passage into the furnace from the wind (including through an air preheater, and a fuel combustion device layer) overcome the resistance of the entire duct fan; furnace outlet to the outlet stack (including a negative pressure outlet furnace, boiler slag tube after anti heating surface portions of the device and the dust removal) all by flue draft fan to overcome the resistance. This ventilation can effectively into the air, and the furnace flue boilers and all run under negative pressure, boiler room of the safety and health conditions better. If compared with negative pressure ventilation, boiler air leakage is small. Currently in heating boilers, the most balanced ventilation. Third, the only positive draft blower mounted in the boiler smoke in the air system, with its head against the resistance of all the smoke duct. Then the furnace and flue boiler are all working under pressure, and thus the furnace wall and door units are required tightly sealed to prevent leakage of flames and smoke high temperature hurt. This ventilation improves the strength of the heat of combustion furnace, boiler smaller volume equivalent capacity. By eliminating air leakage boiler furnace, flues, and improve the thermal efficiency of the boiler. Positive pressure ventilation, currently has applications in the oil and gas boilers. Boiler draft ventilation is generally balanced and positive pressure ventilation. These are the three common boiler ventilation method, in the process, to constantly add fuel, while also promptly clean up the burned ashes.

Beijing SL Pharmaceutical Co., Ltd. as China's key high-tech enterprises, has great influence in the pharmaceutical industry. In early 2017, two-Heron relevant person in charge to get in touch fast boiler izmir, double-Heron Pharmaceutical according to demand, our company to provide a 1-ton split steam condensing steam boiler, and is responsible for subsequent transportation, installation and commissioning work .

"Boiler" what should be changed: generally speaking, the boiler izmir is low utilization of heat energy, emissions of harmful substances more than traditional coal-fired boilers into high thermal efficiency, environmental protection index good clean natural gas boilers. Transformation into the device and then advanced through the premix, and the like of FGR combustion techniques wherein reducing combustion temperature of the fuel in the furnace, so as to achieve the purpose of reducing the emission of nitrogen oxides. Our project coal-fired boiler gas boiler can be changed. Coal was the main provider of energy and power in our country, but due to a variety of harmful substances produced by burning its disadvantages, gradually replaced by other energy sources. Natural gas because of its clean, environmentally friendly features widely loved by the people.