bath natural gas steam water tube boiler price

Contrast gas steam bath steam water tube boiler price and gas steam boiler? Which is more cost-effective? There are new users will ask gas steam boiler and gas steam boiler which is more cost-effective in a number of economic operation? Believed to be ready to buy a steam boiler of every business relationship or personally, with you today, I will work together to analyze these two boilers in operating costs to do a comparison. First, the first point to analyze procurement costs: Because gas steam boiler in the annex above techniques and configurations to be clear leadership and gas steam boiler, gas steam boiler supporting a dedicated burner, a burner just put the cost price opened, so that the same tonnage of steam boilers, steam boilers high gas prices than gas steam boiler more. The second point to analyze construction costs: The costs mainly from the boiler room, boiler tubes of steam investment funds. In which the gas steam boiler because more appropriate auxiliary equipment, so in the boiler room construction funds to be more. There is a gas steam boiler automatic control operation, and automatic alarm and automatic protection function. Connected to the gas pipeline, the burner will automatically supply costs can effectively save staff. Gas-fired steam boiler because of the need of coal on the program, so in terms of personnel expenses wage will be larger. The third point to analyze the environmental cost: major review means that now more stringent gas steam boiler. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used. The fourth point to analyze fuel costs: gas steam boiler will be much higher than the steam boilers in gas fuels. After analyzing the above four points of view than the gas steam boiler Gas steam boiler in order to save more on operating costs, but gas steam boiler environmental protection, now increased pollution than gas steam boiler in environmental protection in recent years so the state more stringent control of environmental pollution, so in accordance with the requirements of environmental protection point of view has an advantage gas steam boiler.

Coal-fired bath steam water tube boiler prices to gas-fired boiler and the basic requirements of a program, the transformation of the basic requirements: 1, the boiler must be carried out in accordance with "Steam Boiler Safety Technology Supervision" and "Hot Water Boiler Safety Technology Supervision" and relevant national technical regulations, construction program should be sent to the local technical supervision departments for approval. 2, to determine the value in use based on the transformation of the boiler has the age and state of the art, taking into account the life expectancy of the boiler. If the boiler use a longer useful life, and the pressure there is a serious corrosion, scaling and overheating phenomena such elements, no transformation of value. 3, boiler walls, chimneys, water supply and air supply, the wind system should remain largely intact. 4, after the transformation of the original technical parameters should be kept constant boiler (operating pressure, temperature, etc.) or the load and to improve the efficiency of the original boiler. 5, after the boiler should comply with national environmental and technical indicators, solve the problem of smoke and dust, meet environmental requirements. 6, when the boiler should try not to change the original pot, and the body is pressed by the original system architecture, covers the smaller the better. 7, rehabilitation programs should be simple, low investment, short construction period and quick, safe and reliable. Second, the transformation method: 1, removal of the original coal-fired boiler slag machine, equipment on coal, dust, chain grate and gearbox. 2, according to the diameter and length of the flame, furnace installation height determining geometric dimensions and the burner. 3, making the furnace, the furnace bottom refractory brick, a semicircular shape. 4, the front arch openings mounted burner nozzle. 5, after that the flame away from the center position of the tube the arch, the arch of the pipe on the basis of the original slope, heightening baffle wall, the protective tube arch. 6, install blast doors. 7, install the induced draft fan drive. 8, the body of the boiler water test pressure 1.5 times the working pressure. 9, the automatic control system installed. Third, the technical proposal: 1, furnace design should consider the flame length and diameter of the flame of the combustion gas, so that the furnace space is filled with the best of the flame, the flame not Wall flush. 2, as the main component of natural gas CH4, H20 generated after combustion, steam share large, so that strong radiation, heating furnace suitably increased to take advantage of the radiation heat transfer, thermal efficiency, reduce the consumption of steel, ensure that the boiler output, and may increase the boiler output. 3, a slight positive pressure within the boiler furnace using a combustion or slightly negative pressure, the sealing performance of the boiler furnace walls to strengthen, not air leakage. 4, due to the smaller excess air ratio of the gas boiler, combustion requires less air flow, coupled with the removal of dust, dust and small flue system, the flue resistance is reduced, a large surplus primer fan flow, using file when the damper plate adjusting the power loss is large, frequency control can be induced draft fan air volume regulation. 5, after the furnace door and see the fire smoke chamber above the chimney, mounted two proof doors, in order to improve the antiknock performance of the boiler. 6, the boiler flue gas the volume of gas in the vapor component is generally 15% to 19%, well above the coal-fired boiler flue gases generated in the water vapor content of 6% by volume or less. Boiler shutdown and startup, due to the low wall temperature of the boiler heating element, when less than less 50 ℃, the flue gas water vapor dew condensation on the wall will, if not removed condensate with the condensate of the contact wall would be C02 acid gas corrosion of furnace wall and the insulation material due to water absorption and thermal insulation effect will be lost. Therefore, before and after the gas hot water boiler smoke box and the rear box and the rear flue smoke condensate discharge means to be provided, promptly boiler condensate removal. 7, the gas boiler-system control function should have combustion process. Pre-blowing may be implemented, auto-ignition, flame detector self-test, automatic load adjustment, flame monitoring, fault alarm interlock shutdown, the gas leak detection valve, induced draft fan and burner control sequential chain protection. 8, in order to prevent fluctuations in the gas pressure regulator to meet the burner requirements, the installation of a gas regulator metering panel outer gas inlet in the boiler room, the surge counter can be accomplished by filtration, regulating, metering, safety shut-off functions.

Battle blue horn sounded, emissions of sulfur, nitrogen and oxygen compounds gradually strict national requirements. To improve the quality of the environment, but also the people a blue sky, in all industries around the environmentally friendly product revolution, Hainan Sinochem Pharmaceutical companies are no exception. By the company investigation and comparison of bath steam water tube boiler price products, in March 2017 signed a six-ton ​​steam-cleaning integrated condensing gas boiler and steam fast boiler. Tested and post feedback, the boiler equipment installation qualification, operating normally, and successfully passed the inspection by local quality inspection departments of the boiler.

It may be suitably improved electrical steam bath steam water tube boiler price burner material: the electric steam boiler at the time of adjusting, if the wind speed control of the secondary is too small, it will lead to too close the gas fire, the burner nozzle so that thermally deformed until failure. Further, when the adjustment is not timely gas boiler load changes the level of the upper orifice of the secondary throttle will be cooled so that the burner is not burning. It may be suitably improved electrical burner of a steam boiler materials, steel materials excellent recommended to choose, and adding wear resistant features. Selection of swirler vanes refractory steel material, so to avoid burning due to swirling vanes configured fall burner opening deformation damage.