Dealer Energy Saving 8t Natural Gas boiler Kuwait

The advantages and disadvantages of natural gas and biomass steam dealer energy saving 8t boiler kuwait steam boiler 1, the price of biomass fuels is greatly affected by seasonal. If the biomass supply is the best, the best option is to choose natural gas. 2, gas pipeline need to connect gas-fired, gas-fired gas pipelines can not be used. 3, the storage of the biomass fuel is more cumbersome than natural gas. 4, biomass boilers are not available in all areas, need to be combined with local boiler policies.

Recently, Luoyang City, Henan Province, pollution prevention campaign of the leading group issued a document required to carry out the transformation of low nitrogen gas dealer energy saving 8t boiler kuwait. Specific content: 10 before the end of the year, within the city steam 4 tons / hour and a gas boiler, and above all the installation of direct-fired burners low nitrogen, 3.5% oxygen in the transformation reference, more than 75% boiler load condition next, particulate matter, sulfur dioxide, nitrogen oxides emission concentration not higher than 5 mg / m, 10 mg / m, 50 mg / m. To complete the transformation of nitrogen oxide emissions monitoring, to wriggle out of the gas boiler outage low nitrogen transformation. After the new gas boiler should be installed low nitrogen burners.

Gas-fired steam dealer energy saving 8t boiler kuwait safety valve from installation to use, it must remain vigilant safety valve is one of the most important components of the gas steam boilers, boiler probability of the risk occurring due to various incidents can effectively suppressed. This article focuses on the safety valve from installation to use several important considerations, we do not ignore the use of gas when it steam boiler. A Notes 1 safety valve, the safety valve should be mounted vertically in a high position in the pot business, set box. 2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly. 4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm. 5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve. 6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. 7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve. 8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve. 9, separable economizer outlet, the steam superheater outlet valve must be installed.

1. oil and gas steam dealer energy saving 8t boiler kuwait system

A complete gas boiler system mainly includes the boiler body, burner, control system and other auxiliary structures