60 tph gas steam boiler in chemical plant

Jinzhou construction and installation company needs an electric heating hot water boiler house construction, after screening and comparison of various brand boiler industry, our excellent results in the cleaning of the boiler industry has been attracted to each other, in mid-2016, the Jinzhou construction and installation the company I signed with an electric heating pressure hot water boiler.

Steam boiler should be noted that when Di operating high specification and 60 tph steam boiler in chemical plant efficiency matters, strong firepower, Di is a common production equipment, but also has some of its own Di dangerous if used improperly, it will cause unnecessary trouble. So master the instructions for use steam boilers, clear during the operation Di Di precautions are necessary. Note that when then the next, the editor based on years of experience, the use of steam boilers with compliance and Di operational considerations summarized below. A steam boiler Use: When the company receives a steam boiler, boiler Di for normal use, as well as business operators Di their own safety, must strictly abide by the "Production Safety Law," "Boiler and Pressure Vessel Safety Supervision Provisional Regulations" "Steam Boiler the relevant provisions of security technology supervision regulations ". This applies to a fixed pressure steam boiler water as a medium, comprising a coal-fired steam boiler, a steam boiler fuel, gas steam boiler. Use of the boiler plant Di technology should have the appropriate certificate, have both technical documentation and construction quality boiler installation supporting information. Enterprises must attach great importance to the boiler safety. Appoint a full-time staff responsible for managing the boiler equipment, improve the management of the use of boilers in accordance with code requirements. Formulate ensure the safe operation of the boiler structure according to the type of boiler, combustion and explosion-proof requirements and procedures, fire prevention, anti-virus and other security management system and the accident approach, in accordance with its strict implementation. Do not drink alcohol and posts and off-site. Boiler should be regularly repair and maintenance, the unit can not be forced to use any security risk boiler. Should be repaired before construction drawings and technical solutions. Repair of technical expertise required reference standards and relevant technical regulations boiler. After completion of repairs, should the pattern, material quality certificate, a certificate of quality inspection and repair and other technical information is stored in the technical archives plant boilers. Non-boiler room operator banned from entering the workplace. Foreign workers must be accompanied by the relevant approval of the leadership or before entering Second, the need to pay attention to Di operational considerations when using the steam boiler: 1, before the boiler must be familiar with the operation manual, simply to protect the safety of the operator and the normal use of the device Di, before starting inspection whether the power supply voltage and the normal operation of the water, close the drain valve, open the water supply valve and check whether the pump stuck, stuck if the water pump cover remove the fan, scroll to the motor shaft can be turned on flexible state inspection or replacement of parts for boilers Turn off the power to avoid live work dangerous. 2, electric control boxes, pump motors and other parts should avoid damp water to prevent burning boiler should pay attention to keep clean, according to the boiler water quality requirements, be sure to install a water softener in use, because they do not use a water softener can cause boiler fouling severe cases can cause burst pipes cut short the life of the boiler. 3, if not in accordance with the provisions of the use of water treatment equipment caused by the above situations are not covered under the warranty, please pay attention when using sewage. To discharge once a day and with a discharge pressure of 0.1MPa-0.15MPa, can prevent clogging pipes, sewage pipes should be properly connected to prevent burns, the flexibility of the safety valve should overhaul, at least once a month to quickly pull the lever to check the safety valve flexibility it off and back seats, the safety valve should be regularly every year to the local technical supervision for verification.

How to ensure the normal operation of the gas 60 tph steam boiler in chemical plant steam boiler gas used in the process in order to ensure the proper and safe use, in the design of on improving the allocation of system protection, common protection system has five steam boilers are: water protection , pressure protection, temperature protection, flame protection, power protection self-locking, followed boiler Co., Ltd. for your details each steam boiler protection system. Gas steam boiler water level to protect the five common protection systems: steam boiler is equipped with two sets of pumps, operation and use. Boiler water level gauge plate supporting one to two, should always be compared with each other, findings indicate inconsistency shall be corrected immediately. Class water level should be flushed, to determine their true level. And also has balanced water level electrode cartridge point can accurately collect to alarm level signal or to control the pump. Common pressure protection systems protect the five gas steam boiler: steam pressure protection: When the boiler pressure exceeds the rated value, the need for chain protection: is shutdown, the system stops the combustion; fire mouth can also be varied, single-stage or two-stage combustion You can also adjust the amount of oil, so the buck, to ensure the safe operation of the boiler. Steam boilers and pressure protection as the water level, the use of multiple protection: safety valve pressure controller. Temperature protection gas steam boiler five common protection systems: temperature protection is an important procedure in the safe operation of the boiler, is particularly important for the regulation and protection of the boiler temperature steam; at the same time to regulate protective role in over-temperature hot water boilers. Prevent explosion of the furnace, the fuel (gas) boiler flame protection means must be provided, is a function of combustion (including ignition, combustion or misfires when halfway off, typically within five seconds re-ignition furnace in the monitoring, within 1 second running off into the oil (gas) solenoid valve, and turns on and audible alarm signal, when the blower continues to operate, the residual gas was purged of combustible furnace, after 20 to 30 seconds purge, automatically cut off the blower and various auxiliary power boiler stop running.) by the flame monitoring and control device component.

The advantages of gas 60 tph steam boiler in chemical plant Gas steam boilers advantage: designers will arrange commandment information again, simple and convenient operation of the facility. Gas-fired steam boiler is not only easy to operate, and as soon as possible to ensure the safety factor used. Energy-saving advantages: high-temperature gas steam boiler with characteristic base pressure, greatly reducing the use of water pressure level heating facilities, to immediately benefit from lower capital injection facilities. Also said that the proportion of raw materials and gas touched. Only proper and adequate oil ignited gas can produce ratios exceeding ignite rate, together with its ability to reduce vapor emissions and maintain two-way power-saving, very convenient. Gas steam boiler can be arranged according to the specific needs of the amount of vapor, reduce renewable resource conservation. The higher the specific requirements and the intermediate supply pairing methodology, the higher the power saving effect. The heat exchanger can continue to use sewage water calories, and thus can increase oxygen supply and drainage of water temperature. In accordance with the provisions of the Environmental Protection useless now need, doing everything, gas-fired industrial equipment is more commonly used. In severe conditions, serious vapor watering, the water content of the salt to enhance the micro gas steam boiler, water hammer audible in steam lines, steam splashing outwardly coupling joint living; or furnace tube if economizer line split, water vapor allowance is given below, when less water is generated, in turn, the situation will occur; less water when severe, it is possible to see the red water wall of furnace tubes can also smell burnt taste. Together, furnace tube will split, could hear explosions. Steam and smoke exclude the furnace mouth and fire security door from. Low water interlock device, if the amount of water is less than the target value, air-conditioning fan, booster fan and grate machine motor reducer operation should be terminated; Security Council water is less than the low water mark, water glass (plate) is black; cleaning sheet is not water clear micro gas steam boiler is not filled or slightly severe filled with water? Ways: first turn off the water level gauge, tap water pipe is connected, and then open the drain cock. If you can see the water line from the top lower, then it is filled with a little water, open the drain valve and place no problem of water. If severe filled with water, please use the emergency shutdown countermeasures.