6ton fire tube thermal oil boiler for casting industry

Burner and flue installation and electrical installation and the fuel supply system of the burner 1, burner 1) before installation read "burner manual", according to the installation requirements. 2) Burner mounting flange, the middle requirements, to ensure the burner to the 6ton fire tube thermal boiler for casting industry flue gas does not leak at the interface. 2, the installation of fuel supply system (see schematic) Note: To prevent a fire caused by generation of static electricity in the fuel tank, the tank should have a good grounding. 1) supply system tank top tank top-feed system suction recommended distance between the back plane and the tubing inside diameter of the oil pump axis, the total length of the suction pipe Hm, m, no greater than DL6-34DL40-75DL100-250Di = 10mmDi = 14mmDi = 16mm0.51.03030401.535452.03535452.540503.0404050 Notes: (1) when there is an elbow or valve on the suction pipe, each of the length of the suction pipe to be minus 0.25m. (2) Di recommended internal diameter suction pipe and return pipe. 2) the distance between the bottom of the tank bottom of the tank supply system supply system pipe inner diameter recommended oil pump axis and a plane, the total length of the suction pipe Hm, m, no greater than DL6-34DL40-75DL100-250Di = 10mmDi = 14mmDi = 16mm1.03030401.535452.03535452.540503.04040504.045 Notes: (1) when there is an elbow or valve on the suction pipe, each of the length of the suction pipe to be minus 0.25m. (2) Di recommended internal diameter suction pipe and return pipe. 3, gas pipe installation requirements Burner gas line itself has been connected, the intake port, the intake pipe bends should be minimized and good sealing performance requirements, to prevent leakage. (Iv) a chimney installation, to prevent leakage, the leakage of smoke, to prevent smoke inhalation chamber. 2, a vertical mounting, a right angle bend bends should be avoided. 3, the top of the chimney must be water-resistant measures. (E) mounting a power switch with electrical connection box 1, the power switch should be considered easy to operate, away from heat, fixation, meet the design requirements. 2, the use of 220V (380V), 50HZ power source, and a ground line. 3, voltage instability in the region use, should be safe regulators. Or affect the normal operation of the combustion engine. 4, the power cord to the electrical box must be connected in strict accordance with the requirements, otherwise, there will be dangerous!

After installation and commissioning fast Boiler professional and technical personnel, two hot water 6ton fire tube thermal boiler for casting industrys to provide our bodies quickly into the orbit of the normal operation. Meanwhile, the design of energy-saving equipment also effectively improve the thermal efficiency of the boiler, saved us a huge amount of fuel costs. --customer feedback

For customers who want to know the price of oil and gas 6ton fire tube thermal boiler for casting industrys, they should first confirm the use of the gas boilers they want to purchase, and secondly consider the brand, tonnage, model, boiler operating costs and after-sales service. In this way, you can purchase a gas boiler at the right price. For example, the WNS1-1.25-Q boiler produced by ZBG has a production standard of GB. The price of such a boiler body is about US$17,769. If it includes various valves, meters, economizers, feed pumps, burners and other auxiliary equipment accessories, the full set price is about US$29,545. Such a price is already very affordable for a high-quality energy-saving and environmentally-friendly oil and gas boiler. Such a boiler itself has high thermal efficiency and automatic operation, which greatly reduces the operating cost of the boiler.

The gas burner is configured by the five gas burner system components 1 structure, the air supply system consists of the following five system. Function into the air supply system is to a certain wind speed and amount of air to the combustion chamber, its main components are: a housing, fan motors, fan impeller, air guns fire tube, damper controller, damper baffle, a cam adjustment mechanism, diffusion plate. 2, the ignition system. The function of the ignition system ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas 6ton fire tube thermal boiler for casting industry manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 3, the monitoring system. The function of the burner to ensure the safe and stable operation, the main components are flame detectors, pressure monitors, temperature monitors and the like. 4, the fuel system. Function of the fuel system is to ensure that the desired fuel burner. The fuel oil burner system are: tubing and fittings, pumps, solenoid valves, nozzles, heavy oil preheater. The gas burner mainly a filter, pressure regulator, solenoid valve, and then firing solenoid valve, the fuel valve. 5, electronic control system. Electronic control system is the command center and the focal point for the above system, the main control element is a control box, for different burner with a different programmer, common control box has: LFL series, LAL series, LOA series, LGB series the main difference is the time of each different program steps.